Skip to Content
Merck
CN
  • Urine homogentisic acid and tyrosine: simultaneous analysis by liquid chromatography tandem mass spectrometry.

Urine homogentisic acid and tyrosine: simultaneous analysis by liquid chromatography tandem mass spectrometry.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2014-06-22)
A T Hughes, A M Milan, P Christensen, G Ross, A S Davison, J A Gallagher, J J Dutton, L R Ranganath
ABSTRACT

Alkaptonuria (AKU) is a rare debilitating autosomal recessive disorder of tyrosine metabolism. Deficiency of homogentisate 1,2-dioxygenase results in increased homogentisic acid (HGA) which although excreted in gram quantities in the urine, is deposited as an ochronotic pigment in connective tissues, especially cartilage. Ochronosis leads to a severe, early-onset form of osteoarthritis, increased renal and prostatic stone formation and hardening of heart vessels. Treatment with the orphan drug, Nitisinone, an inhibitor of the enzyme 4-hydroxyphenylpyruvate dioxygenase has been shown to reduce urinary excretion of HGA, resulting in accumulation of the upstream pre-cursor, tyrosine. Using reverse phase LC-MS/MS, a method has been developed to simultaneously quantify urinary HGA and tyrosine. Using matrix-matched calibration standards, two product ion transitions were identified for each compound and their appropriate isotopically labelled internal standards. Validation was performed across the AKU and post-treatment concentrations expected. Intrabatch accuracy for acidified urine was 96-109% for tyrosine and 94-107% for HGA; interbatch accuracy (n=20 across ten assays) was 95-110% for tyrosine and 91-109% for HGA. Precision, both intra- and interbatch was <10% for tyrosine and <5% for HGA. Matrix effects observed with acidified urine (12% decrease, CV 5.6%) were normalised by the internal standard. Tyrosine and HGA were proved stable under various storage conditions and no carryover, was observed. Overall the method developed and validated shows good precision, accuracy and linearity appropriate for the monitoring of patients with AKU, pre and post-nitisinone therapy.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, ≥99.9%
Supelco
Methanol, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Methanol, analytical standard
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Supelco
Acetonitrile(Neat), Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Supelco
Residual Solvent - Acetonitrile(solution in DMSO), Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Methanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Methanol, BioReagent, ≥99.93%
Sigma-Aldrich
Methanol, puriss., meets analytical specification of Ph Eur, ≥99.7% (GC)
Sigma-Aldrich
Methanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Methanol, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
Methanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Methanol, anhydrous, 99.8%
Sigma-Aldrich
Methanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Methanol, purification grade, 99.8%
Sigma-Aldrich
Methanol, suitable for NMR (reference standard)
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
DL-Tyrosine, 99%
Sigma-Aldrich
Methanol solution, contains 0.50 % (v/v) triethylamine
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acetonitrile, ReagentPlus®, 99%
Sigma-Aldrich
Acetonitrile, ACS reagent, ≥99.5%
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
USP
Residual Solvent Class 2 - Acetonitrile, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Sigma-Aldrich
Acetonitrile, suitable for HPLC-GC, ≥99.8% (GC)
Sigma-Aldrich
Acetonitrile, ≥99.5% (GC)
Supelco
Acetonitrile, analytical standard