Merck
CN
  • Highly selective enrichment of baicalin in rat plasma by boronic acid-functionalized core-shell magnetic microspheres: Validation and application to a pharmacokinetic study.

Highly selective enrichment of baicalin in rat plasma by boronic acid-functionalized core-shell magnetic microspheres: Validation and application to a pharmacokinetic study.

Talanta (2015-11-26)
Taomin Huang, Ya Xiong, Nianzu Chen, Donglei Wang, Yonghua Lai, Chunhui Deng
ABSTRACT

To the best of our knowledge, this study is the first to successfully apply a novel, highly selective enrichment technique based on boronic acid-functionalized core-shell magnetic microspheres (BA-Fe3O4@SiO2-Au@mSiO2) with a large surface area and uniform pore size, to determine the baicalin concentration in rat plasma by HPLC. By taking advantage of the special interaction between boronic acid and baicalin under alkaline conditions, as well as the microspheres' size exclusion ability, baicalin was selectively extracted from protein-rich biosamples, such as plasma, without any other pretreatment procedure except for a 10-min vortexing step. BA-Fe3O4@SiO2-Au@mSiO2 microsphere-adsorbed baicalin was straightforwardly and rapidly isolated from the matrix using a magnet. Baicalin was subsequently eluted from the microspheres under acidic conditions for 2min for further HPLC analysis. The extraction conditions, such as the amount of microspheres added, adsorption time, adsorption pH, and elution time and pH, were also determined. Furthermore, method validation, including the linear range, detection limit, precision, accuracy, and recovery, were determined. This newly developed method based on BA-Fe3O4@SiO2-Au@mSiO2 microspheres is a simple, accurate, selective, and green analytical preparatory technique for analyzing baicalin in rat plasma. This study will be further novel research on the analysis of complex plasma samples and the pharmacokinetics of drugs similar to baicalin.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Ethylene glycol, ReagentPlus®, ≥99%
Sigma-Aldrich
Ethylene glycol, Vetec, reagent grade, 98%
Sigma-Aldrich
4-Nitrophenol, ReagentPlus®, ≥99%
Sigma-Aldrich
Styrene, ReagentPlus®, contains 4-tert-butylcatechol as stabilizer, ≥99%
Supelco
Ethanol solution, certified reference material, 2000 μg/mL in methanol
Sigma-Aldrich
Ethylene glycol, BioUltra, ≥99.5% (GC)
Sigma-Aldrich
(3-Aminopropyl)triethoxysilane, ≥98%
Sigma-Aldrich
Ethanol Fixative 80% v/v, suitable for fixing solution (blood films)
Supelco
Ethanol standards 10% (v/v), 10 % (v/v) in H2O, analytical standard
Sigma-Aldrich
Citrate Concentrated Solution, BioReagent, suitable for coagulation assays, 4 % (w/v)
Sigma-Aldrich
Silver nitrate solution, 2.5 % (w/v) AgNO3 in H2O
Sigma-Aldrich
Citrate Concentrated Solution, BioUltra, for molecular biology, 1 M in H2O
Sigma-Aldrich
Butylamine, ≥99%
Sigma-Aldrich
(3-Aminopropyl)triethoxysilane, 99%
Sigma-Aldrich
Butylamine, 99.5%
Sigma-Aldrich
Silver nitrate on silica gel, extent of labeling: ~10 wt. % loading, +230 mesh
Sigma-Aldrich
(3-Aminopropyl)triethoxysilane, ≥98.0%
Sigma-Aldrich
Ethylene glycol, spectrophotometric grade, ≥99%
Sigma-Aldrich
Ethylene glycol, anhydrous, 99.8%
Sigma-Aldrich
(3-Aminopropyl)triethoxysilane, packaged for use in deposition systems, ≥98%
Supelco
Styrene, analytical standard
Sigma-Aldrich
Ammonia-14N, 99.99 atom % 14N
Sigma-Aldrich
Silver nitrate, BioXtra, >99% (titration)
Sigma-Aldrich
Silver nitrate, BioReagent, suitable for plant cell culture, >99% (titration)
Sigma-Aldrich
8-Aminopyrene-1,3,6-trisulfonic acid trisodium salt, BioReagent, suitable for fluorescence, ≥96.0% (HPCE)
Sigma-Aldrich
8-Aminopyrene-1,3,6-trisulfonic acid trisodium salt, ≥96.0% (HPCE), solid
Sigma-Aldrich
Ethyl alcohol, Pure, 190 proof, meets USP testing specifications
Sigma-Aldrich
Ethyl alcohol, Pure, 190 proof, ACS spectrophotometric grade, 95.0%
Sigma-Aldrich
4-Nitrophenol solution, 10 mM
Sigma-Aldrich
Silver nitrate, 99.9999% trace metals basis