Skip to Content
Merck
CN
  • The development of a new disposable pipette extraction phase based on polyaniline composites for the determination of levels of antidepressants in plasma samples.

The development of a new disposable pipette extraction phase based on polyaniline composites for the determination of levels of antidepressants in plasma samples.

Journal of chromatography. A (2015-05-09)
Andréa R Chaves, Bruno H F Moura, Juciene A Caris, Denilson Rabelo, Maria Eugênia C Queiroz
ABSTRACT

In the present work, a new stationary phase for disposable pipette extraction (DPX) based on composites of polyaniline and a styrene-divinylbenzene (SD) copolymer was applied to the analysis of fluoxetine and norfluoxetine in plasma samples using liquid chromatography and fluorescence detector (LC-FD). The DPX variables, such as number of draw/eject cycles, sample pH, type and volume of the desorption solvent, were optimized to established the sorption equilibrium and shorten the analysis time. Among the DPX evaluated variables, the higher extraction efficiency were obtained with 200 μL of plasma mixed with 200 μL of borate solution (pH 9), followed by liquid desorption of the drug with 200 μL acetonitrile in a single cycle. The DPX/LC-FD method demonstrated a linear response over the dynamic range from 10 to 1000 ng mL(-1) for fluoxetine and from 80 ng mL(-1) (LOQ) to 1000 ng mL(-1) for norfluoxetine with r(2)=0.997 and 0.998, respectively. The limit of quantification (LOQ) was 10 ng mL(-1) for fluoxetine and 80 ng mL(-1) for norfluoxetine. Based on the analytical validation results, the proposed method can be a useful tool for determining the fluoxetine and norfluoxetine levels in plasma samples from patients receiving therapeutic dosages.

MATERIALS
Product Number
Brand
Product Description

Supelco
Hydrochloric acid solution, volumetric, 0.1 M HCl (0.1N), endotoxin free
Sigma-Aldrich
Luperox® A75, Benzoyl peroxide, 75%, remainder water
Sigma-Aldrich
Benzoyl peroxide blend with dicyclohexyl phthalate, suitable for use as a catalyst for electron microscopy. Modified to render it safe in transit.
Sigma-Aldrich
Nitric-14N acid solution, ~10 N in H2O, 99.99 atom % 14N
Sigma-Aldrich
1,4-Dioxane, anhydrous, 99.8%, contains <=25 ppm BHT as stabilizer
Sigma-Aldrich
Sulfuric acid, 99.999%
Sigma-Aldrich
Aniline, ACS reagent, ≥99.5%
Sigma-Aldrich
Aniline, ReagentPlus®, 99%
Sigma-Aldrich
Hydrochloric acid solution, for amino acid analysis, ~6 M in H2O
Sigma-Aldrich
Hydrochloric acid solution, 1.0 N, BioReagent, suitable for cell culture
Sigma-Aldrich
Hydrochloric acid, 36.5-38.0%, BioReagent, Molecular Biology
Sigma-Aldrich
Hydrochloric acid solution, 32 wt. % in H2O, FCC
Sigma-Aldrich
Luperox® A75FP, Benzoyl peroxide, 75% remainder water, contains 25 wt. % water as stabilizer, 75%
Sigma-Aldrich
Acetone, ≥99%, FCC, FG
Sigma-Aldrich
Acetone, natural, ≥97%
Sigma-Aldrich
Nitric acid, 70%, purified by redistillation, ≥99.999% trace metals basis
Sigma-Aldrich
Nitric acid, ACS reagent, ≥90.0%