Skip to Content
Merck
CN
  • Synthesis and biological characterization of a promising F-18 PET tracer for vesicular acetylcholine transporter.

Synthesis and biological characterization of a promising F-18 PET tracer for vesicular acetylcholine transporter.

Bioorganic & medicinal chemistry (2015-07-04)
Zhude Tu, Xiang Zhang, Hongjun Jin, Xuyi Yue, Prashanth K Padakanti, Lihai Yu, Hui Liu, Hubert P Flores, Kota Kaneshige, Stanley M Parsons, Joel S Perlmutter
ABSTRACT

Nine fluorine-containing vesicular acetylcholine transporter (VAChT) inhibitors were synthesized and screened as potential PET tracers for imaging the VAChT. Compound 18a was one of the most promising carbonyl-containing benzovesamicol analogs; the minus enantiomer, (-)-18a displayed high potency (VAChT Ki=0.59 ± 0.06 nM) and high selectivity for VAChT versus σ receptors (>10,000-fold). The radiosynthesis of (-)-[(18)F]18a was accomplished by a two-step procedure with 30-40% radiochemical yield. Preliminary biodistribution studies of (-)-[(18)F]18a in adult male Sprague-Dawley rats at 5, 30, 60 and 120 min post-injection (p.i.) were promising. The total brain uptake of (-)-[(18)F]18a was 0.684%ID/g at 5 min p.i. and by 120 min p.i. slowly washed out to 0.409 %ID/g; evaluation of regional brain uptake showed stable levels of ∼0.800 %ID/g from 5 to 120 min p.i in the VAChT-enriched striatal tissue of rats, indicating the tracer had crossed the blood brain barrier and was retained in the striatum. Subsequent microPET brain imaging studies of (-)-[(18)F]18a in nonhuman primates (NHPs) showed high striatal accumulation in the NHP brain; the standardized uptake value (SUV) for striatum reached a maximum value of 5.1 at 15 min p.i. The time-activity curve for the target striatal region displayed a slow and gradual decreasing trend 15 min after injection, while clearance of the radioactivity from the cerebellar reference region was much more rapid. Pretreatment of NHPs with 0.25mg/kg of the VAChT inhibitor (-)-vesamicol resulted in a ∼90% decrease of striatal uptake compared to baseline studies. HPLC metabolite analysis of NHP plasma revealed that (-)-[(18)F]18a had a good in vivo stability. Together, these preliminary results suggest (-)-[(18)F]18a is a promising PET tracer candidate for imaging VAChT in the brain of living subjects.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Ammonium formate, ≥99.995% trace metals basis
Sigma-Aldrich
1,3-Di-o-tolylguanidine, 99%
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Sigma-Aldrich
Ammonium formate solution, BioUltra, 10 M in H2O
Supelco
Ammonium formate solution, 10 mM in H2O, suitable for HPLC
Sigma-Aldrich
Acetonitrile, Preparateur, ≥99.9% (GC), One-time steel-plastic (SP) drum
Sigma-Aldrich
Tantalum(V) ethoxide, 99.98% trace metals basis
Tantalum(V) ethoxide, packaged for use in deposition systems
Sigma-Aldrich
Acetonitrile, electronic grade, 99.999% trace metals basis