Merck
CN
  • Tablet formulation of an active pharmaceutical ingredient with a sticking and filming problem: direct compression and dry granulation evaluations.

Tablet formulation of an active pharmaceutical ingredient with a sticking and filming problem: direct compression and dry granulation evaluations.

Drug development and industrial pharmacy (2013-11-28)
Naveen K Bejugam, Shravan K Mutyam, Gita N Shankar
ABSTRACT

To develop a tablet formulation for an active pharmaceutical ingredient for which sticking and filming problems occurred during tablet punching. Direct compression and dry granulation tableting techniques were evaluated using factorial experimental design. The effects of chrome-coated punch tips, filler types and active percent in the tablet formulation by direct compression were evaluated. Similarly, for dry granulation using the roller compaction technique, three formulation factors - roller compaction pressure, intragranular filler percent and filler type - were studied. Tablets prepared by both techniques were characterized in regard to their compressibility index, tablet hardness, disintegration time, friability index and stickiness-filming index (an arbitrary index). Ten formulations were prepared by each technique. Using multiple response optimizations and estimated response surface plots, the data were analyzed to identify optimum levels for the formulation factors. Compressibility index values for all the formulations prepared by direct compression exceeded 25%, unlike the blends prepared by dry granulation. Both tablet hardness and disintegration time for direct compression formulations were significantly lower than for dry granulation formulations. The friability index values were significantly higher for direct compression formulations than for dry granulation formulations. All the direct compression formulations, unlike the dry granulation formulations, had a high stickiness-filming index. Statistical analysis helped in identifying the optimum levels of formulation factors, as well as the method for eliminating sticking and filming. Unlike the direct compression technique, dry granulation yielded tablets for which sticking and filming were completely eliminated.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Trifluoroacetic acid, suitable for HPLC, ≥99.0%
Supelco
Residual Solvent - Acetonitrile, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Hydrochloric acid, meets analytical specification of Ph. Eur., BP, NF, fuming, 36.5-38%
Sigma-Aldrich
Trifluoroacetic acid, puriss. p.a., suitable for HPLC, ≥99.0% (GC)
Sigma-Aldrich
Hydrochloric acid, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., fuming, ≥37%, APHA: ≤10
Sigma-Aldrich
Hydrochloric acid, ACS reagent, 37%
Sigma-Aldrich
Trifluoroacetic acid, ≥99%, for protein sequencing
Sigma-Aldrich
Trifluoroacetic acid, ReagentPlus®, 99%
Supelco
Trifluoroacetic acid, analytical standard
Sigma-Aldrich
Hydrochloric acid, 36.5-38.0%, BioReagent, for molecular biology
Supelco
Acetonitrile, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Hydrogen chloride solution, 1.0 M in acetic acid
Sigma-Aldrich
Acetonitrile, ≥99.5% (GC)
Sigma-Aldrich
Acetonitrile, biotech. grade, ≥99.93%
Sigma-Aldrich
Acetonitrile, ACS reagent, ≥99.5%
Sigma-Aldrich
Acetonitrile, suitable for DNA synthesis, ≥99.9% (GC)
USP
Residual Solvent Class 2 - Acetonitrile, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Hydrochloric acid, puriss., 24.5-26.0%
Sigma-Aldrich
Acetonitrile, Preparateur, ≥99.9% (GC), One-time steel-plastic (SP) drum
Sigma-Aldrich
Acetonitrile, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
Hydrochloric acid solution, 32 wt. % in H2O, FCC
Sigma-Aldrich
Acetonitrile, ReagentPlus®, 99%
Sigma-Aldrich
Acetonitrile, suitable for HPLC-GC, ≥99.8% (GC)
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acetonitrile, for HPLC, for UV, ≥99.9% (GC)
Supelco
Hydrogen chloride – ethanol solution, ~1.25 M HCl, for GC derivatization, LiChropur
Supelco
Hydrogen chloride – 2-propanol solution, ~1.25 M HCl (T), for GC derivatization, LiChropur
Supelco
Acetonitrile, analytical standard
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%