Merck
CN
  • Identification and quantification of phytochemicals in nutraceutical products from green tea by UHPLC-Orbitrap-MS.

Identification and quantification of phytochemicals in nutraceutical products from green tea by UHPLC-Orbitrap-MS.

Food chemistry (2014-12-04)
Noelia López-Gutiérrez, Roberto Romero-González, Patricia Plaza-Bolaños, José Luis Martínez Vidal, Antonia Garrido Frenich
ABSTRACT

A method has been developed and validated for the simultaneous detection and quantification of phytochemicals in nutraceutical products obtained from green tea. For that purpose, ultra-high performance liquid chromatography coupled to single-stage Orbitrap high resolution mass spectrometry (UHPLC-Orbitrap-MS) has been used. A database containing 37 compounds has been used for the detection and identification of the target compounds. The developed methodology was based on solid-liquid extraction, using a mixture of methanol:H2O (80:20, v/v, pH 4), followed by dilution (10 times) with a mixture of ammonium acetate:methanol (50:50, v/v). Chromatographic conditions were optimised and full scan accurate mass data acquisition using electrospray ionisation in positive and negative ion mode was used. Moreover, all-ion fragmentation mode was used to get information of fragment ions, and they were used for identification purposes. The developed method was validated, obtaining repeatability (intra-day) and inter-day precision values (expressed as relative standard deviation, RSD) lower than 16% and 20%, respectively. Lower limits were also evaluated and limits of detection (LODs) ranged from 1 to 50 μg L(-1), while limits of quantification (LOQs) ranged from 2 to 150 μg L(-1). Recovery was performed at five levels and it ranged from 70% to 109%. Finally, this method was used to evaluate the phytochemical content in 10 samples (tablets or capsules), showing concentrations of (+)-catechin, (-)-epicatechin, gallic acid, (-)-gallocatechin and quercetin-3-O-rutinoside, ranging from 258 (C6) to 10,729 (C6) mg kg(-1).

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
(−)-Gallocatechin, ≥98% (HPLC)
Sigma-Aldrich
(−)-Epigallocatechin, ≥95% (HPLC), from green tea
Sigma-Aldrich
(−)-Gallocatechin gallate, from green tea, ≥98% (HPLC)
Sigma-Aldrich
Genistein, from Glycine max (soybean), ~98% (HPLC)
Sigma-Aldrich
Apigenin, ≥95.0% (HPLC)
Sigma-Aldrich
Taurocholic acid sodium salt hydrate, BioXtra, ≥95% (HPLC)
Supelco
(−)-Gallocatechin, analytical standard
Chlorogenic acid, primary reference standard
Supelco
Genistein, analytical standard
Supelco
Apigenin, analytical standard
Supelco
(−)-Epigallocatechin, analytical standard
Supelco
Quercetin, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Residual Solvent - Acetonitrile, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
(−)-Gallocatechin gallate, analytical standard
Epigallocatechin, primary reference standard
Chlorogenic acid, European Pharmacopoeia (EP) Reference Standard
Sigma-Aldrich
Formic acid, ACS reagent, ≥96%
Sigma-Aldrich
Formic acid, ≥95%, FCC, FG
Sigma-Aldrich
Taurocholic acid sodium salt hydrate, ≥95% (HPLC)
Sigma-Aldrich
Chlorogenic acid, ≥95% (titration)
Sigma-Aldrich
Acetic acid, natural, ≥99.5%, FG
Sigma-Aldrich
Acetic acid, ≥99.5%, FCC, FG
Sigma-Aldrich
Acetic acid-12C2, 99.9 atom % 12C
Sigma-Aldrich
Methanol solution, contains 0.50 % (v/v) triethylamine
Sigma-Aldrich
Quercetin, ≥95% (HPLC), solid
Sigma-Aldrich
Genistein, synthetic, ≥98% (HPLC), powder
Sigma-Aldrich
Methanol solution, NMR reference standard, 4% in methanol-d4 (99.8 atom % D), NMR tube size 3 mm × 8 in.
USP
Quercetin, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Formic acid, reagent grade, ≥95%
Ferulic acid, European Pharmacopoeia (EP) Reference Standard