Merck
CN
  • Simultaneous quantitative determination of microcystin-LR and its glutathione metabolites in rat liver by liquid chromatography-tandem mass spectrometry.

Simultaneous quantitative determination of microcystin-LR and its glutathione metabolites in rat liver by liquid chromatography-tandem mass spectrometry.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2014-06-16)
Xiaochun Guo, Ping Xie, Jun Chen, Xun Tuo, Xuwei Deng, Shangchun Li, Dezhao Yu, Cheng Zeng
ABSTRACT

The roles of glutathione (GSH) and cysteine (Cys) in the detoxification of Microcystin-LR (MC-LR) have recently become a popular area of research. However, lacking analysis methods for MC-LR-GSH and MC-LR-Cys (two main GSH pathway metabolites) in mammals, elucidation of the detoxification mechanism and metabolic pathway of MC-LR in mammals is difficult. In this study, a novel method for the simultaneous quantitative analysis of MC-LR, MC-LR-GSH and MC-LR-Cys in rat liver was developed and validated. The analytes were simultaneously extracted from rat liver using 3M sodium chloride solution containing 0.01M EDTA-Na2-5% acetic acid, followed by solid-phase extraction (SPE) on Oasis HLB and silica cartridges and determination by liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS/MS). Under the optimized pretreatment conditions and instrument parameters, good recoveries of MC-LR, MC-LR-GSH and MC-LR-Cys were obtained at three concentrations (0.2, 1.0 and 2.5 μg g(-1) dry weight (DW)) with values ranging from 97.7 ± 4.2 to 98.7 ± 5.1%, 70.1 ± 4.8 to 71.1 ± 4.1% and 79.8 ± 3.5 to 81.4 ± 4.0%, respectively. The relative standard deviations (RSDs) of these compounds at 0.2, 1.0 and 2.5 μg g(-1) DW were between 4.3% and 6.9%. The limits of detection (LODs) were 0.005, 0.007 and 0.006 μg g(-1) DW and the limits of quantification (LOQs) were 0.017, 0.023 and 0.020 μg g(-1) DW for MC-LR, MC-LR-GSH and MC-LR-Cys, respectively. Furthermore, this method was successfully applied to both time- and dosage-effect studies of MC-LR, MC-LR-GSH and MC-LR-Cys in vivo.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Formic acid, ≥95%, FCC, FG
Sigma-Aldrich
Acetic acid, natural, ≥99.5%, FG
Sigma-Aldrich
Acetic acid-12C2, 99.9 atom % 12C
Supelco
Residual Solvent - Acetonitrile, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Formic acid, ACS reagent, ≥96%
Sigma-Aldrich
Formic acid, reagent grade, ≥95%
Sigma-Aldrich
Acetic acid, ≥99.5%, FCC, FG
Sigma-Aldrich
Methanol solution, NMR reference standard, 4% in methanol-d4 (99.8 atom % D), NMR tube size 3 mm × 8 in.
Sigma-Aldrich
Methanol solution, contains 0.50 % (v/v) triethylamine
Sigma-Aldrich
L-Cysteine, BioUltra, ≥98.5% (RT)
Supelco
Acetic acid, analytical standard
Sigma-Aldrich
Acetic acid, for luminescence, BioUltra, ≥99.5% (GC)
Sigma-Aldrich
L-Cysteine, 97%
Sigma-Aldrich
L-Cysteine, ≥97%, FG
Sigma-Aldrich
Formic acid solution, BioUltra, 1.0 M in H2O
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Sigma-Aldrich
Methanol, anhydrous, 99.8%
Sigma-Aldrich
Methanol, NMR reference standard
Sigma-Aldrich
Methanol-12C, 99.95 atom % 12C
Supelco
L-Cysteine, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Sigma-Aldrich
Methanol, purification grade, 99.8%
Millipore
Bifido Selective Supplement B, suitable for microbiology
Supelco
Methanol, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Acetonitrile, Preparateur, ≥99.9% (GC), One-time steel-plastic (SP) drum
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Acetic acid, glacial, ACS reagent, ≥99.7%
Sigma-Aldrich
Acetic acid, glacial, puriss., meets analytical specification of Ph. Eur., BP, USP, FCC, 99.8-100.5%
Sigma-Aldrich
Methanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Acetic acid, glacial, ReagentPlus®, ≥99%
Sigma-Aldrich
Acetonitrile, ReagentPlus®, 99%