Skip to Content
Merck
CN
  • Multi-drug and metabolite quantification in postmortem blood by liquid chromatography-high-resolution mass spectrometry: comparison with nominal mass technology.

Multi-drug and metabolite quantification in postmortem blood by liquid chromatography-high-resolution mass spectrometry: comparison with nominal mass technology.

Journal of analytical toxicology (2014-09-14)
Thomas G Rosano, Seo Na, Kenneth Ihenetu, Thomas A Swift, Michelle Wood
ABSTRACT

High-resolution mass spectrometry (HRMS) is being applied in postmortem drug screening as an alternative to nominal mass spectrometry, and additional evaluation in quantitative casework is needed. We report quantitative analysis of benzoylecgonine, citalopram, cocaethylene, cocaine, codeine, dextromethorphan, dihydrocodeine, diphenhydramine, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine, hydrocodone, hydromorphone, meperidine, methadone, morphine, oxycodone and oxymorphone in postmortem blood by ultra-performance liquid chromatography (UPLC)-MS(E)/time-of-flight (TOF). The method employs analyte-matched deuterated internal standardization and MS(E) acquisition of precursor and product ions at low (6 eV) and ramped (10-40 eV) collision energies, respectively. Quantification was performed using precursor ion data obtained with a mass extraction window of ± 5 ppm. Fragment and residual precursor ion acquisitions at ramped collision energies were evaluated as additional analyte identifiers. Extraction recovery of >60% and matrix effect of <20% were determined for all analytes and internal standards. Defined limits of detection (10 ng/mL) and quantification (25 ng/mL) were validated along with a linearity analytical range of 25-3,000 ng/mL (R(2) > 0.99) for all analytes. Parallel UPLC-MS(E)/TOF and UPLC-MS/MS analysis showed comparable precision and bias along with concordance of 253 positive (y = 1.002x + 1.523; R(2) = 0.993) and 2,269 negative analyte findings in 159 postmortem cases. Analytical performance and correlation studies demonstrate accurate quantification by UPLC-MS(E)/TOF and extended application of HRMS in postmortem casework.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Acetic acid, ≥99.5%, FCC, FG
Sigma-Aldrich
Acetic acid-12C2, 99.9 atom % 12C
Sigma-Aldrich
Acetic acid, natural, ≥99.5%, FG
Supelco
Acetic acid, analytical standard
Sigma-Aldrich
Acetic acid, suitable for luminescence, BioUltra, ≥99.5% (GC)
Supelco
Acetonitrile(Neat), Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Acetic acid, glacial, ≥99.99% trace metals basis
Sigma-Aldrich
Acetic acid, glacial, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8%
Sigma-Aldrich
Acetic acid, glacial, puriss., 99-100%
Sigma-Aldrich
Acetic acid, glacial, ReagentPlus®, ≥99%
Sigma-Aldrich
Acetic acid, glacial, puriss., meets analytical specification of Ph. Eur., BP, USP, 99.8-100.5%
Sigma-Aldrich
Acetic acid, glacial, ACS reagent, ≥99.7%
Sigma-Aldrich
Acetic acid solution, suitable for HPLC
Supelco
Residual Solvent - Acetonitrile(solution in DMSO), Pharmaceutical Secondary Standard; Certified Reference Material
Leucine, European Pharmacopoeia (EP) Reference Standard
Sigma-Aldrich
Dichloromethane, anhydrous, ≥99.8%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Millipore
Bifido Selective Supplement B, suitable for microbiology
Supelco
5α-Androstan-17β-ol-3-one, VETRANAL®, analytical standard
Sigma-Aldrich
Acetonitrile, Preparateur, ≥99.9% (GC), One-time steel-plastic (SP) drum
Sigma-Aldrich
DL-Leucine, ≥99% (HPLC)
Supelco
Dichloromethane, Selectophore, ≥99.5%
Sigma-Aldrich
Dichloromethane, suitable for HPLC, ≥99.9%, contains 40-150 ppm amylene as stabilizer
Supelco
Acetonitrile, analytical standard
Sigma-Aldrich
Acetonitrile, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
Ammonium hydroxide solution, BioUltra, ~1 M NH3 in H2O (T)
Sigma-Aldrich
Formic acid, ≥95%, FCC, FG
Sigma-Aldrich
Formic acid solution, BioUltra, 1.0 M in H2O
Supelco
Dichloromethane, analytical standard
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%