  • Ultra-high performance liquid chromatography-electrospray tandem mass spectrometry for the analysis of antibiotic residues in environmental waters.

Ultra-high performance liquid chromatography-electrospray tandem mass spectrometry for the analysis of antibiotic residues in environmental waters.

Environmental science and pollution research international (2015-06-25)
Qiang Xue, Yanjie Qi, Fei Liu
ABSTRACT

An optimized solid-phase extraction (SPE) and ultra-high performance liquid chromatography-electrospray tandem mass spectrometry (UPLC-MS/MS) method was developed for the effective analysis of 35 antibiotics including sulfonamides (SAs), quinolones (QLs), tetracyclines (TCs), macrolides (MALs), lincomycin (LIN), and chloramphenicol (CAP). The addition of 0.1% formic acid to the mobile phase was favorable for the formation of [M + H](+) and the enhancement in the detection signals, but using ammonium formate decreased [M + H](+) with a corresponding reduction in the response of CAP. The optimal pH range for the SPE was 4.5 ∼ 5.0 with 6 mL aqueous ammonia/methanol (5/95, v/v) as the optimized eluent. An internal standard (IS) was selected for each type of analytes based on similarities in classification and retention time. The detection was completed in less than 10 min and was excellent with method detection limits (MDL) of 0.29 ∼ 4.03 ng/L. The recoveries of the antibiotics in samples from ultrapure water and groundwater were 67.13 ∼ 93.00% and 68.91 ∼ 92.67%, respectively. The antibiotics in samples collected from wastewater, surface water, and groundwater were also effectively detected. This newly developed method has the advantages of short detection times, small sample consumption, excellent reproducibility, and high sensitivity. This provides a reliable and promising technique for the simultaneous detection and monitoring of various residual antibiotics in aqueous environmental samples.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Ammonium formate, ≥99.995% trace metals basis
Sigma-Aldrich
2,3-Diaminonaphthalene, BioReagent, suitable for fluorescence, ≥98.0% (HPLC)
Sigma-Aldrich
Methanol, anhydrous, 99.8%
Sigma-Aldrich
2,3-Diaminonaphthalene, ≥95% (HPLC), powder
Sigma-Aldrich
Erythromycin, potency: ≥850 μg per mg
Sigma-Aldrich
Doxorubicin hydrochloride, 98.0-102.0% (HPLC)
Sigma-Aldrich
Erythromycin, meets USP testing specifications
Sigma-Aldrich
Tetracycline, 98.0-102.0% (HPLC)
Sigma-Aldrich
Methanol, purification grade, 99.8%
Sigma-Aldrich
Methanol, suitable for NMR (reference standard)
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Methanol, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
Erythromycin, BioReagent, suitable for cell culture
Sigma-Aldrich
Ammonium formate, reagent grade, 97%
Sigma-Aldrich
Methanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Methanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Methanol, puriss., meets analytical specification of Ph Eur, ≥99.7% (GC)
Sigma-Aldrich
Methanol, BioReagent, ≥99.93%
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Supelco
Ammonium formate solution, 10 mM in H2O, suitable for HPLC
Sigma-Aldrich
Ammonium formate solution, BioUltra, 10 M in H2O
Sigma-Aldrich
Methanol solution, suitable for NMR (reference standard), 4% in methanol-d4 (99.8 atom % D), NMR tube size 3 mm × 8 in.
Sigma-Aldrich
Methanol solution, contains 0.50 % (v/v) triethylamine
Sigma-Aldrich
Decylamine, 95%
Sigma-Aldrich
Decylamine, ≥99.0% (GC)
Sigma-Aldrich
Sparfloxacin, ≥98.0% (HPLC)
Sigma-Aldrich
Nalidixic acid, ≥98%
Sigma-Aldrich
Ofloxacin, fluoroquinolone antibiotic
Sigma-Aldrich
Oxolinic acid, quinolone antibiotic