Skip to Content
Merck
CN

Measurement of Blood Volume in Adult Rhesus Macaques (Macaca mulatta).

Journal of the American Association for Laboratory Animal Science : JAALAS (2015-12-04)
Theodore R Hobbs, Steven W Blue, Byung S Park, Jennifer J Greisel, P Michael Conn, Francis K-Y Pau
ABSTRACT

Most biomedical facilities that use rhesus macaques (Macaca mulatta) limit the amount of blood that may be collected for experimental purposes. These limits typically are expressed as a percentage of blood volume (BV), estimated by using a fixed ratio of blood (mL) per body weight (kg). BV estimation ratios vary widely among facilities and typically do not factor in variables known to influence BV in humans: sex, age, and body condition. We used indicator dilution methodology to determine the BV of 20 adult rhesus macaques (10 male, 10 female) that varied widely in body condition. We measured body composition by using dual-energy X-ray absorptiometry, weight, crown-to-rump length, and body condition score. Two indicators, FITC-labeled hydroxyethyl starch (FITC-HES) and radioiodinated rhesus serum albumin ((125)I-RhSA), were injected simultaneously, followed by serial blood collection. Plasma volume at time 0 was determined by linear regression. BV was calculated from the plasma volume and Hct. We found that BV calculated by using FITC-HES was consistently lower than BV calculated by using (125)I-RhSA. Sex and age did not significantly affect BV. Percentage body fat was significantly associated with BV. Subjects categorized as having 'optimal' body condition score had 18% body fat and 62.1 mL/kg BV (by FITC-HES; 74.5 mL/kg by (125)I-RhSA). Each 1% increase in body fat corresponded to approximately 1 mL/kg decrease in BV. Body condition score correlated with the body fat percentage (R(2) = 0.7469). We provide an equation for calculating BV from weight and body condition score.

MATERIALS
Product Number
Brand
Product Description

Supelco
Ethanol solution, certified reference material, 2000 μg/mL in methanol
Sigma-Aldrich
Ethanol Fixative 80% v/v, suitable for fixing solution (blood films)
Supelco
Ethanol standards 10% (v/v), 10 % (v/v) in H2O, analytical standard
Sigma-Aldrich
Ethyl alcohol, Pure 190 proof, for molecular biology
Sigma-Aldrich
Ethyl alcohol, Pure, 200 proof, anhydrous, ≥99.5%
Sigma-Aldrich
Ethylenediaminetetraacetic acid solution, 0.02% in DPBS (0.5 mM), sterile-filtered, BioReagent, suitable for cell culture
Sigma-Aldrich
Ethylenediaminetetraacetic acid, anhydrous, crystalline, BioReagent, suitable for cell culture
Sigma-Aldrich
Ethylenediaminetetraacetic acid, purified grade, ≥98.5%, powder
Sigma-Aldrich
Ethylenediaminetetraacetic acid, BioUltra, anhydrous, ≥99% (titration)
Sigma-Aldrich
Ethylenediaminetetraacetic acid, 99.995% trace metals basis
Sigma-Aldrich
Ethyl alcohol, Pure, 190 proof, ACS spectrophotometric grade, 95.0%
Sigma-Aldrich
Ethyl alcohol, Pure, 190 proof, meets USP testing specifications
Sigma-Aldrich
Ethylenediaminetetraacetic acid, ACS reagent, 99.4-100.6%, powder
Sigma-Aldrich
Ethyl alcohol, Pure, 190 proof, ACS reagent, meets USP testing specifications, Excise Tax-free, Permit for use required
Sigma-Aldrich
Ethyl alcohol, Pure, 160 proof, Excise Tax-free, Permit for use required
Sigma-Aldrich
Ethyl alcohol, Pure, 200 proof, ACS reagent, meets USP testing specifications, Excise Tax-free, Permit for use required
Sigma-Aldrich
Ethyl alcohol, Pure, 200 proof, ACS reagent, ≥99.5%
Sigma-Aldrich
Ethyl alcohol, Pure, 200 proof, meets USP testing specifications
Sigma-Aldrich
Ethyl alcohol, Pure 200 proof, Molecular Biology
Sigma-Aldrich
Ethanol, puriss. p.a., absolute, ≥99.8% (GC)
Sigma-Aldrich
Ethyl alcohol, Pure, 200 proof
Sigma-Aldrich
Ethylenediaminetetraacetic acid, Vetec, reagent grade, 98%