Skip to Content
Merck
CN
  • Application of plastic polymers in remediating wine with elevated alkyl-methoxypyrazine levels.

Application of plastic polymers in remediating wine with elevated alkyl-methoxypyrazine levels.

Food additives & contaminants. Part A, Chemistry, analysis, control, exposure & risk assessment (2015-04-22)
Andreea Botezatu, Gary J Pickering
ABSTRACT

3-Alkyl-2-methoxypyrazines (MPs) are odour-active compounds that elicit atypical green aromas and flavours in some wines, and are resilient to removal using traditional wine-making approaches. They originate either as contaminants from Coccinellidae beetles inadvertently introduced during wine processing ("ladybug taint") or as grape-derived constituents that are undesirable at elevated levels. In this study we investigated the capacity of a selection of plastic polymers to reduce concentrations of three MPs: isopropyl methoxypyrazine (IPMP), secbutyl methoxypyrazine (SBMP) and isobutyl methoxypyrazine (IBMP). In Trial 1, red wine was spiked with IPMP (20 ng/l), SBMP (20 ng/l) and IBMP (20 ng/l), then separately treated with 13 plastic polymers (surface area 350 cm(2)/l). Three polymers were then identified for further testing based on the results from Trial 1: silicone, ethylene and vinyl acetate (EVA) and a poly-lactic acid-based biodegradable polymer. In Trial 2, the efficacy of these selected polymers to reduce MP levels in red wine was tested as a function of contact time. Solid-phase micro-extraction multi-dimensional GC-MS was used to measure MP levels before and after treatment with the polymers. Results showed significant reductions in all target odorants after 24 h treatment: silicone reduced IPMP and IBMP by 96% and 100%, respectively, while the biodegradable polymer decreased IPMP and IBMP concentrations by 52% and 36%, respectively. EVA was less effective in lowering MP levels (7% IPMP and 23% IBMP after 24 h). Taken overall, the data suggest the potential for the use of poly-lactic acid and silicone in treating wines contaminated by ladybug taint, as well as in reducing high levels of grape-derived MPs.

MATERIALS
Product Number
Brand
Product Description

Supelco
SPME Fiber Assembly, 65 μm PDMS/DVB, Metal Alloy (1 cm), needle size 23 ga, Autosampler, pk of 1, pink hub
Supelco
SPME Fiber Assembly, 60 μm PEG, Metal Alloy (1 cm), needle size 23 ga, Manual Holder, pk of 3, purple hub
Sigma-Aldrich
D-(−)-Fructose, 98.0-102.0% dry basis, meets USP testing specifications
Supelco
SPME Sampling Stand, for use with 4 mL vials
Supelco
SPME Fiber Assembly, 100 μm PDMS, Fused Silica (1 cm), needle size 24 ga, Autosampler, pk of 3, red hub
Supelco
SPME Portable Field Sampler, coating PDMS/DVB
Supelco
SPME Fiber Assembly, 7 μm PDMS, Fused Silica (1 cm), needle size 24 ga, Manual Holder, pk of 3, green hub
Supelco
SPME Fiber Assembly, 75 μm CAR/PDMS, Fused Silica (1 cm), needle size 24 ga, Autosampler, pk of 3, black hub
Supelco
SPME Fiber Assembly, 100 μm PDMS, Fused Silica (1 cm), needle size 23 ga, Autosampler, pk of 3, red hub
Supelco
SPME Fiber Assembly, 30 μm PDMS, Fused Silica (1 cm), needle size 24 ga, Manual Holder, pk of 3, yellow hub
Supelco
SPME Fiber Assembly, 85 μm CAR/PDMS, StableFlex (1 cm), needle size 24 ga, Manual Holder, pk of 3, light blue hub
Supelco
SPME Fiber Assembly, 75 μm CAR/PDMS, Fused Silica (1 cm), needle size 24 ga, Manual Holder, pk of 3, black hub
Supelco
SPME Fiber Assembly, 85 μm Polyacrylate, Fused Silica (1 cm), needle size 24 ga, Manual Holder, pk of 3, white hub
Supelco
SPME Fiber Assembly, 75 μm CAR/PDMS, Fused Silica (1 cm), needle size 23 ga, Autosampler, pk of 3, black hub
Supelco
SPME Fiber Assembly, 75 μm CAR/PDMS, Fused Silica (1 cm), needle size 23 ga, Manual Holder, pk of 3, black hub
Supelco
SPME Fiber Assembly, 65 μm PDMS/DVB, Fused Silica (1 cm), needle size 24 ga, Manual Holder, pk of 3, blue hub
Supelco
SPME Fiber Assembly, 30 μm PDMS, Fused Silica (1 cm), needle size 24 ga, Autosampler, pk of 3, yellow hub
Supelco
SPME Fiber Assembly, 65 μm PDMS/DVB, Fused Silica (1 cm), needle size 24 ga, Autosampler, pk of 3, blue hub
Supelco
SPME Fiber Assembly, 65 μm PDMS/DVB, StableFlex (1 cm), needle size 24 ga, Manual Holder, pk of 3, pink hub
Supelco
SPME Fiber Assembly, 65 μm PDMS/DVB, StableFlex (1 cm), needle size 24 ga, Autosampler, pk of 3, pink hub
Supelco
SPME Fiber Assembly, 65 μm PDMS/DVB, Fused Silica (1 cm), needle size 23 ga, Manual Holder, pk of 3, blue hub
Supelco
SPME Fiber Assembly, 50/30µm DVB/CAR/PDMS, StableFlex (2cm), needle size 24 ga, Autosampler, pk of 3, notched gray hub
Sigma-Aldrich
Sodium chloride solution, 0.85%
Sigma-Aldrich
Sodium chloride, random crystals, 99.9% trace metals basis
Sigma-Aldrich
Sodium chloride-35Cl, 99 atom % 35Cl
Supelco
SPME Portable Field Sampler, coating PDMS
Supelco
SPME Fiber Assembly, 100 μm PDMS, Fused Silica (1 cm), needle size 24 ga, Manual Holder, pk of 3, red hub
Supelco
SPME Fiber Assembly, 7 μm PDMS, Fused Silica (1 cm), needle size 24 ga, Autosampler, pk of 3, green hub
Supelco
SPME Fiber Assembly, 50/30µm DVB/CAR/PDMS, StableFlex (1 cm), needle size 24 ga, Autosampler, pk of 3, plain gray hub
Supelco
SPME Fiber Assembly, 85 μm Polyacrylate, Fused Silica (1 cm), needle size 24 ga, Autosampler, pk of 3, white hub