Skip to Content
Merck
CN

LC-MS Anlaysis of Pain Managment Opiates on Ascentis® Express Biphenyl, 30 x 2.1 mm

LC-MS Anlaysis of Pain Managment Opiates on Ascentis® Express Biphenyl, 30 x 2.1 mm application for LC-MS

Materials

related product

Product No.
Description
Pricing

Codeine solution

1 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®

(±)-Methadone solution

1 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®

Hydromorphone solution

1 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®

Buprenorphine solution

1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®

Pain Management Multi-component Opiate Mixture-13 solution

100 μg/mL each component (10 μg/mL Fentanyl), ampule of 1.0 mL, certified reference material, Cerilliant®

Fentanyl solution

1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®

Hydrocodone solution

1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®

Morphine solution

100 μg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®

Meperidine solution

1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®

Naloxone solution

1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®

Naltrexone solution

1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®

Oxycodone solution

1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®

Oxymorphone solution

1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®

cis-Tramadol hydrochloride solution

1.0 mg/mL in methanol (as free base), ampule of 1 mL, certified reference material, Cerilliant®

Ascentis® Express Biphenyl Column

2.7 μm particle size, L × I.D. 3 cm × 2.1 mm

CONDITIONS

column

Ascentis Express Biphenyl, 3 cm x 2.1 mm, 2.7 μm particles (64054-U)

mobile phase

[A] water with 0.1% formic acid; [B] acetonitrile with 0.1% formic acid;

gradient

10 to 20% B in 0.75 min; to 95% B in 1.5 min

flow rate

0.3 mL/min

pressure

2125 psi (147 bar)

column temp.

30 °C

detector

MS-TOF, ESI+

injection

2 μL

sample

50-500 ng/mL in 99:1, water:methanol

Description

Analysis Note

This application demonstrates the separation of 13 pain managment opiates on the Ascentis Express Biphenyl using an LC-TOF mass spectrometer. This application demonstrates the scalability of this method to 30 x 2.1 mm column geometry using the 2.7 um biphenyl phase. The method provides baseline resolution of all isobaric sets of interest.

Legal Information

Ascentis is a registered trademark of Merck KGaA, Darmstadt, Germany