CHVE72HS3

Millipore Express® SHR High Area with prefilter 0.5/0.1µm Cartridge 20

Code 0 Silicone, Autoclavable and SIP

别名:

Millipore Express® SHRP High Area, Cartridge

登录 查看组织和合同定价。

选择规格

变更视图

关于此项目

UNSPSC Code:
23151806
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助


产品名称

Millipore Express® SHR w/Prefilter High Area Cartridge, Chemistry: 0.5 / 0.1 µm Hydrophilic Polyethersulfone (PES) Configuration: 20 in. Code 7

Quality Segment

material

polypropylene support, silicone seal

reg. compliance

meets FDA 21 CFR 177-182 (all component materials)

sterility

non-sterile

sterilization compatibility

autoclavable compatible
steam-in-place compatible

product line

Millipore Express®

feature

hydrophilic, with prefilter

manufacturer/tradename

Millipore Express®

parameter

≤108.4 mL/min air diffusion at 3.45 bar (50 psig) (in water), 1700 mbar max. differential pressure (25 psi) at 80 °C (Forward), 1700 mbar max. inlet pressure (25 psi) at 80 °C (Forward), 2100 mbar max. inlet pressure (30 psi) at 25 °C (Reverse), 340 mbar max. differential pressure (5 psi) at 135 °C (Forward), 340 mbar max. inlet pressure (5 psi) at 135 °C (Forward), 69 mbar max. inlet pressure (1 psi) at 135 °C (Reverse), 6900 mbar max. differential pressure (100 psi) at 25 °C (Forward), 6900 mbar max. inlet pressure (100 psi) at 25 °C (Forward)

technique(s)

sterile filtration: suitable

L

20 in.

W

2.8 in.

cartridge nominal length

20 in. (50 cm)

filter diam.

2.7 in. (6.9 cm)

filter filtration area

2.0 m2

filter size

20 in.

impurities

≤0.25 EU/mL bacterial endotoxins (LAL test, aqueous extraction), <0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

matrix

Millipore Express® SHR (w/Prefilter High Area)

pore size

0.5/0.1 μm pore size

bubble point

≥2586 mbar (37.5 psig), nitrogen with 70/30% IPA/water

cartridge code

Code 7

General description

Cartridge Type: Liquid
Device Configuration: Cartridge

Packaging

Double Easy-Open bag

Preparation Note

Sterilization Method: 5 autoclave cycles of 60 min at 126 °C or 5 forward SIP cycles of 30 min at 135 °C

This product was manufactured with a MILLIPORE EXPRESS® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Analysis Note

After sterilization and a controlled water flush of 40 L, samples exhibited <500 ppb TOC per USP 643 and <1.3 μS/cm per USP 645 at 25 °C.

Bacterial Retention: Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 107 CFU/cm2 using ASTM® F838 methodology.

Other Notes

Directions for Use
  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer wetting instructions of Filters with MILLIPORE EXPRESS® Membrane user guide
  • Storage Statement: Please refer Filters with MILLIPORE EXPRESS® Membrane user guide
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.

Legal Information

ASTM is a registered trademark of American Society for Testing and Materials
MILLIPORE EXPRESS is a registered trademark of Merck KGaA, Darmstadt, Germany


Still not finding the right product?




使用 Emprove® 计划保持符合 GMP 要求

使用Emprove® Dossiers可加快资格认证、保持合规性并节省时间。

下载 Dossiers

注意:您将进入 EmproveSuite.com。您的用户名和密码与 SigmaAldrich.com 是分开的,可能不同

免费注册,几分钟内即可访问 Emprove® Dossiers 升级您的订阅计划,解锁 Emprove® Suite 中的高级定制内容。

没有找到您要找的内容?访问 Emprove® 计划帮助页面

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库