跳转至内容
Merck
CN

KHGEG006FH3

Millipore Express® SHC 0.5/0.2µm, Opticap® XL 600 Capsule

Fittings 3/4 in. TC- 9/16 in. HB, Gamma Compatible

别名:

Opticap Gamma Compatible XL 600 Millipore Express SHC 0.5/0.2 μm 3/4 in. TC-9/16 in. HB

登录 查看组织和合同定价。

选择尺寸


关于此项目

UNSPSC Code:
23151806
NACRES:
NB.24
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助

产品名称

Millipore Express® SHC,Opticap® XL囊式, inlet connection diam. 3/4 in., Opticap® XL 600, pore size 0.5/0.2 μm, cartridge nominal length 6.5 in. (16.5 cm)

material

polyethersulfone
polyethylene support
polypropylene (gamma-stable)
polypropylene housing
polypropylene vent cap (Gamma stable)
polysulfone
silicone seal

reg. compliance

meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)

sterility

non-sterile

sterilization compatibility

gamma compatible

product line

Opticap® XL 600

feature

gamma compatible
hydrophilic

manufacturer/tradename

Millipore Express®

parameter

≤3.7 mL/min air diffusion at 2.8 bar (40 psig) and 23 °C (in water)
1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
100 psi max. differential pressure (6.9 bar) (intermittent)
2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent)
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 23 °C
6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent)
6.9 bar max. inlet pressure (100 psi) at 23 °C (intermittent)
80 psi max. differential pressure (5.5 bar) (continuous)
80 psig max. inlet pressure

technique(s)

sterile filtration: suitable

L

16.5 cm (6.5 in.)

W

2.2 in.

cartridge nominal length

6.5 in. (16.5 cm)

diam.

5.6 cm (2.2 in.)

filtration area

590 cm2

inlet connection diam.

3/4 in.

inlet to outlet W

16.5 cm (6.5 in.)

outlet connection diam.

9/16 in.

impurities

≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

matrix

Millipore Express® SHC

pore size

0.5/0.2 μm pore size

bubble point

≥4000 mbar (58 psig), air with water at 23 °C

fitting

1/4 in. drain/vent hose barb (with double O-ring seal)
inlet sanitary flange
outlet hose barb
(19 mm (3/4 in.) Sanitary Flange Inlet and 14 mm (9/16 in.) Hose Barb Outlet)

Quality Level

正在寻找类似产品? 访问 产品对比指南

Analysis Note

TOC/电导率
在灭菌和3.0 L的受控水冲洗后,样品在25 °C下显示出低于500 ppb TOC(根据USP<64>)和低于1.3 µS/cm(根据USP<64>)。
用水冲洗 ≥1 L 后,将满足 USP 可氧化物质测试要求
细菌保留
使用ASTM® F838方法,对样品进行最小保留的缺陷短波单孢菌挑战浓度为 1 × 10⁷ CFU/cm² 的定量保留。

Disclaimer

EMD Millipore Corporation保证,本品符合欧盟承压设备指令(European Pressure Equipment Directive, 97/23/EC of 29 May 1997)要求。本品依照欧盟承压设备指令Article 3 § 3条款要求分类。其设计和制造符合合理的工程实践,以确保安全使用。根据承压设备指令Article 3 § 3条款要求,本品不带CE标志。

General description

设备配置:胶囊

Other Notes

使用说明

  • 生物截留:微生物
  • 作用机制:过滤(体积排阻)
  • 应用:生物处理
  • 预期用途:减少或去除微生物/生物负荷
  • 使用说明:请参见《OPTICAP® XL Capsules and OPTICAP® XLT胶囊用户指南》中的安装部分
  • 储存说明:干燥储存
  • 处置声明:根据国家、省市和当地适用法规处置。

这些产品在符合FDA药品生产质量管理规范的工厂生产。

Packaging

双层易开袋

Preparation Note

本产品采用符合21 CFR 210.3(b)(6)中规定的“无纤维释放”过滤器标准的Millipore Express®膜制造。
灭菌方法
耐受45kGy伽马射线辐照剂量;123°C×60 min高压锅蒸汽灭菌,3次;不可在线蒸汽灭菌

Legal Information

ASTM is a registered trademark of American Society for Testing and Materials
MILLIPORE EXPRESS is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany

分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系客户支持