  • Prediction of the zeta potentials and ionic descriptors of a silica hydride stationary phase with mobile phases of different pH and ionic strength.

Prediction of the zeta potentials and ionic descriptors of a silica hydride stationary phase with mobile phases of different pH and ionic strength.

Analytica chimica acta (2015-01-28)
Chadin Kulsing, Yuanzhong Yang, Maria T Matyska, Joseph J Pesek, Reinhard I Boysen, Milton T W Hearn
ABSTRACT

In this study, the zeta potentials of a silica hydride stationary phase (Diamond Hydride™) in the presence of different water-acetonitrile mixtures (from 0-80% (v/v) acetonitrile) of different ionic strengths (from 0-40mM) and pH values (from pH 3.0-7.0) have been investigated. Debye-Hückel theory was applied to explain the effect of changes in the pH and ionic strength of these aqueous media on the negative zeta potential of this stationary phase. The experimental zeta potentials of the Diamond Hydride™ particles as a function of acetonitrile content up to 50% (v/v) correlated (R(2)=0.998) with the predicted zeta potential values based on this established theory, when the values of the dissociation constant of all related species, as well as viscosity, dielectric constant and refractive index of the aqueous medium were taken into consideration. Further, the retention behavior of basic, acidic and neutral analytes was investigated under mobile phase conditions of higher pH and lower ionic strength. Under these conditions, the Diamond Hydride™ stationary phase surface became more negative, as assessed from the increasingly more negative zeta potentials, resulting in the ion exchange characteristics becoming more dominant and the basic analytes showing increasing retention. Ionic descriptors were derived from these chromatographic experiments based on the assumption that linear solvation energy relationships prevail. The results were compared with predicted ionic descriptors based on the different calculated zeta potential values resulting in an overall correlation of R(2)=0.888. These studies provide fundamental insights into the impact on the separation performance of changes in the zeta potential of the Diamond Hydride™ surface with the results relevant to other silica hydride and, potentially, to other types of stationary phase materials.

MATERIALS
Product Number
Brand
Product Description

Supelco
Ammonium formate, eluent additive for LC-MS, LiChropur, ≥99.0%
Sigma-Aldrich
Ammonium formate, BioUltra, ≥99.0% (calc. based on dry substance, NT)
Sigma-Aldrich
Ammonium formate, ≥99.995% trace metals basis
Supelco
Residual Solvent - Acetonitrile(solution in DMSO), Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Acetonitrile(Neat), Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Ammonium formate, reagent grade, 97%
Supelco
Ammonium formate solution, 10 mM in H2O, suitable for HPLC
Sigma-Aldrich
Formic acid solution, BioUltra, 1.0 M in H2O
Sigma-Aldrich
β-D-Allose, rare aldohexose sugar
Sigma-Aldrich
Ammonium formate solution, BioUltra, 10 M in H2O
Sigma-Aldrich
Acetonitrile, ReagentPlus®, 99%
Sigma-Aldrich
Acetonitrile, suitable for HPLC-GC, ≥99.8% (GC)
Sigma-Aldrich
Acetonitrile, ≥99.9% (GC)
Sigma-Aldrich
Acetonitrile, ACS reagent, ≥99.5%
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acetonitrile, Preparateur, ≥99.9% (GC), One-time steel-plastic (SP) drum
Sigma-Aldrich
Acetonitrile, electronic grade, 99.999% trace metals basis
Supelco
Acetonitrile, analytical standard
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Sigma-Aldrich
Formic acid, ≥95%, FCC, FG
Sigma-Aldrich
Acetonitrile, ≥99.5% (GC)
Sigma-Aldrich
Acetonitrile, biotech. grade, ≥99.93%
Sigma-Aldrich
Acetonitrile, suitable for DNA synthesis, ≥99.9% (GC)
USP
Residual Solvent Class 2 - Acetonitrile, United States Pharmacopeia (USP) Reference Standard