Metrological traceability in mass spectrometry-based targeted protein quantitation: a proof-of-principle study for serum apolipoproteins A-I and B100.

Journal of proteomics (2014-06-28)
Nico P M Smit, Fred P H T M Romijn, Irene van den Broek, Jan W Drijfhout, Martin Haex, Arnoud van der Laarse, Yuri E M van der Burgt, Christa M Cobbaert
ABSTRACT

In this study, we have followed up on previous liquid chromatography (LC) multiple reaction monitoring (MRM) mass spectrometry (MS) approaches for measurement of apolipoprotein (apo) A-I and apo B100 in serum aiming for implementation of a multiplexed assay in a clinical chemistry laboratory with full metrological traceability. Signature peptides were selected and detected by dynamic MRM, and stable isotope labeled (SIL)-peptides were used as internal standards. Five apo A-I and four apo B100 peptides were measured in serum digests with linearity (R(2)>0.992) in the physiologically relevant concentration ranges. Linearity with regard to protein concentration was ascertained at five concentration levels (R(2)>0.926 and R(2)>0.965, for the apo A-I and apo B100 peptides, respectively). Three native value-assigned sera were used as external calibrators for further method verification. Imprecision values on sample preparation and LC-MS/MS acquisition were below the established minimal specifications for apo A-I and apo B100 (5.0% and 5.3%, respectively). Correlation of LC-MS/MS results with immunoturbidimetric assay results, for normo- and hypertriglyceridemic samples, showed R(2)>0.944 for apo A-I and R(2)>0.964 for apo B100. This LC-MS/MS method has potential for clinical application in normo- and dyslipidemic patients. Measurement of apo A-I and apo B100 may offer an alternative to high and low density lipoprotein cholesterol (HDL-c and LDL-c) methods for cardiovascular disease risk assessment in dyslipidemic patients [1]. An LC-MS/MS method for apo A-I and apo B100 has the advantage of antibody independent and specific detection of protein signature peptides. The introduction of an LC-MS/MS method for apo A-I and apo B100 can serve as an example for many existing and newly developed (multiplex) biomarker methods in quantitative clinical chemistry proteomics (qCCP). Such LC-MS/MS methods should meet basic clinical chemistry principles with regard to test evaluation [2]. Criteria for imprecision should be pre-defined, e.g., based on biological variation. The use of commutable and traceable serum-based calibrators will improve inter-laboratory reproducibility of LC-MS/MS methods and may contribute to a more rapid transition of biomarker discovery to clinical utility with benefit for the patient treatment and improvement of general health care.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Methanol, anhydrous, 99.8%
Sigma-Aldrich
L-Leucine, BioUltra, ≥99.5% (NT)
Sigma-Aldrich
Urea solution, BioUltra, ~8 M in H2O
Sigma-Aldrich
DL-Dithiothreitol, ≥99.0% (RT)
Supelco
Methanol, analytical standard
Supelco
2,2,2-Trifluoroethanol, analytical standard, suitable for NMR (spectroscopy)
Supelco
3-Indoleacetic acid, PESTANAL®, analytical standard
Sigma-Aldrich
Urea-12C, 99.9 atom % 12C
Sigma-Aldrich
L-Leucine, 99%, FG
Sigma-Aldrich
DL-Dithiothreitol, BioUltra, Molecular Biology, ≥99.5% (RT)
Supelco
L-Leucine, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Methanol, suitable for NMR (reference standard)
Supelco
L-Leucine, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Sigma-Aldrich
DL-Dithiothreitol solution, BioUltra, Molecular Biology, ~1 M in H2O
Sigma-Aldrich
3-Indoleacetic acid, suitable for plant cell culture, crystalline
Sigma-Aldrich
3-Indoleacetic acid, 98%
Sigma-Aldrich
Urea solution, 40 % (w/v) in H2O
Sigma-Aldrich
L-Leucine, reagent grade, ≥98% (HPLC)
Sigma-Aldrich
DL-Dithiothreitol, suitable for electrophoresis, ≥99%
Sigma-Aldrich
DL-Dithiothreitol, BioXtra, ≥99.0% (titration)
Sigma-Aldrich
DL-Dithiothreitol, Molecular Biology, ≥98% (HPLC), ≥99% (titration)
Sigma-Aldrich
L-Leucine, from non-animal source, meets EP, JP, USP testing specifications, suitable for cell culture, 98.5-101.0%
Sigma-Aldrich
DL-Dithiothreitol, ≥98% (HPLC), ≥99.0% (titration)
Sigma-Aldrich
Methanol, purification grade, 99.8%
Supelco
DL-Dithiothreitol solution, 1 M in H2O
Supelco
Methanol, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Methanol, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Millipore
Urea solution, suitable for microbiology, 40% in H2O
Sigma-Aldrich
DL-Dithiothreitol, Vetec, reagent grade, 98%