Skip to Content
Merck
CN
  • Biodistribution evaluation of icaritin in rats by ultra-performance liquid chromatography-tandem mass spectrometry.

Biodistribution evaluation of icaritin in rats by ultra-performance liquid chromatography-tandem mass spectrometry.

Journal of ethnopharmacology (2014-08-03)
Shuang-Qing Zhang
ABSTRACT

Icaritin (ICT) is a major bioactive prenylflavonoid derivative contained in the Epimedium which is a widely used herbal medicine for the treatment of infertility, impotence, cardiovascular and skeletal diseases listed in the Chinese Pharmacopoeia. The aim of this study is to investigate the tissue distribution of ICT in rats by ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) MATERIALS AND METHODS: ICT was intraperitoneally administrated to rats for 7 consecutive days at dose levels of 20, 40 and 60 mg/kg/day, respectively. Various tissue homogenates were pretreated by protein precipitation with acetonitrile. ICT and internal standard coumestrol were separated on a BEH C18 column with a gradient mobile phase and detected using precursor-product ion transitions of m/z 367.1→297.1 for ICT and 267.0→211.1 for coumestrol at the negative ionization mode, respectively. ICT was widely distributed in rat's various tissues and its concentrations in tissues increased with elevated doses. A sensitive and reliable UPLC-MS/MS method was firstly established to quantify ICT in rat tissues. The lower limit of quantification was 0.5 ng/mL based on 100 μL of tissue homogenates. The intra- and inter-day accuracy at all levels fell in the ranges of 90.8-103.4% and 91.6-100.3%, and the intra- and inter-day precision (RSD) were in the ranges of 2.9-10.5% and 2.6-9.1%, respectively. The UPLC-MS/MS showed good accuracy, precision and recovery and was suitable for the quantification of ICT in rat tissues. Wide distribution of ICT could helpfully elucidate systemic effects and various functions of ICT.

MATERIALS
Product Number
Brand
Product Description

Supelco
Acetonitrile(Neat), Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Ammonium formate, BioUltra, ≥99.0% (calc. based on dry substance, NT)
Supelco
Ammonium formate, eluent additive for LC-MS, LiChropur, ≥99.0%
Sigma-Aldrich
Ammonium formate, reagent grade, 97%
Sigma-Aldrich
Ammonium formate, ≥99.995% trace metals basis
Supelco
Residual Solvent - Acetonitrile(solution in DMSO), Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acetonitrile, ReagentPlus®, 99%
Sigma-Aldrich
Acetonitrile, ACS reagent, ≥99.5%
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
USP
Residual Solvent Class 2 - Acetonitrile, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Sigma-Aldrich
Acetonitrile, suitable for HPLC-GC, ≥99.8% (GC)
Sigma-Aldrich
Acetonitrile, ≥99.5% (GC)
Supelco
Acetonitrile, analytical standard
Sigma-Aldrich
Acetonitrile, ≥99.9% (GC)
Sigma-Aldrich
Acetonitrile, biotech. grade, ≥99.93%
Sigma-Aldrich
Acetonitrile, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
Ammonium formate solution, BioUltra, 10 M in H2O
Supelco
Ammonium formate solution, 10 mM in H2O, suitable for HPLC
Sigma-Aldrich
Acetonitrile, Preparateur, ≥99.9% (GC), One-time steel-plastic (SP) drum
Sigma-Aldrich
Acetonitrile, suitable for DNA synthesis, ≥99.9% (GC)