Skip to Content
Merck
CN
  • Quantitative analysis of glycerol levels in human urine by liquid chromatography-tandem mass spectrometry.

Quantitative analysis of glycerol levels in human urine by liquid chromatography-tandem mass spectrometry.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2014-03-25)
Ying Dong, Yanhua Ma, Kuan Yan, Li Shen, Xiaobing Wang, Youxuan Xu, Genye He, Yun Wu, Jianghai Lu, Zhiyong Yang, Feifei Feng
ABSTRACT

Glycerol has the latent capacity to act as a plasma volume expander and disguise blood doping practices. Therefore, it has been prohibited in sports as a masking agent by the World Anti-Doping Agency (WADA) since January 2010 and a urinary threshold (1mg/mL) was recommended recently [1]. The purpose of this study was to establish and validate a novel quantitative method for the determination of urinary glycerol concentrations using a liquid chromatography-tandem mass spectrometry approach. This simple yet highly specific method made use of the derivatization of glycerol by benzoyl chloride in aqueous solution at 40°C followed by analysis via LC-ESI-MS/MS without sample pre-concentration or cleanup. The assay was linear over the concentration range of 1.0-1000μg/mL for glycerol in human urine. The lower limit of detection (LLOD) and lower limit of quantitation (LLOQ) were 0.3μg/mL and 1.0μg/mL, respectively. The intra- and inter-day precision of the method at three concentration levels (3, 500 and 900μg/mL) was less than 12.2%. The method also afforded satisfactory results in terms of accuracy, derivatization yield, extraction recovery, matrix effect and specificity. The method has been successfully applied to the detection of glycerol in "Quality Assurance Program" samples provided by the World Association of Anti-Doping Scientists (WAADS) and routine doping-control samples in our laboratory.

MATERIALS
Product Number
Brand
Product Description

Supelco
Residual Solvent - Acetonitrile(solution in DMSO), Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Benzoyl chloride, ReagentPlus®, ≥99%
Sigma-Aldrich
Benzoyl chloride, ACS reagent, 99%
Sigma-Aldrich
Glycerol solution, 83.5-89.5% (T)
Sigma-Aldrich
Glycerol solution, puriss., meets analytical specification of Ph. Eur., BP, 84-88%
USP
Glycerin, United States Pharmacopeia (USP) Reference Standard
Supelco
Ammonium formate, eluent additive for LC-MS, LiChropur, ≥99.0%
Sigma-Aldrich
Ammonium formate, BioUltra, ≥99.0% (calc. based on dry substance, NT)
Sigma-Aldrich
Ammonium formate, reagent grade, 97%
Sigma-Aldrich
Ammonium formate, ≥99.995% trace metals basis
Supelco
Acetonitrile(Neat), Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Glycerin, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Acetonitrile, Preparateur, ≥99.9% (GC), One-time steel-plastic (SP) drum
Supelco
Acetonitrile, analytical standard
Sigma-Aldrich
Glycerol, puriss., anhydrous, 99.0-101.0% (alkalimetric)
Sigma-Aldrich
Ammonium formate solution, BioUltra, 10 M in H2O
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acetonitrile, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
Acetonitrile, ReagentPlus®, 99%
Sigma-Aldrich
Acetonitrile, biotech. grade, ≥99.93%
Sigma-Aldrich
Acetonitrile, ACS reagent, ≥99.5%
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Sigma-Aldrich
Hexane, Laboratory Reagent, ≥95%
Sigma-Aldrich
Hexane, HPLC Plus, for HPLC, GC, and residue analysis, ≥95%
Supelco
Hexane, analytical standard
Sigma-Aldrich
Hexane, suitable for HPLC, ≥95%
Supelco
Glycerol, analytical standard
Sigma-Aldrich
Hexane, ReagentPlus®, ≥99%
Sigma-Aldrich
Glyceryl tribenzoate, 95%