Skip to Content
Merck
CN
  • Exploring the possibilities of capacitively coupled contactless conductivity detection in combination with liquid chromatography for the analysis of polar compounds using aminoglycosides as test case.

Exploring the possibilities of capacitively coupled contactless conductivity detection in combination with liquid chromatography for the analysis of polar compounds using aminoglycosides as test case.

Journal of pharmaceutical and biomedical analysis (2015-01-01)
Péter Jankovics, Shruti Chopra, Mohamed N El-Attug, Deirdre Cabooter, Kris Wolfs, Béla Noszál, Ann Van Schepdael, Erwin Adams
ABSTRACT

The analysis of highly polar (often charged) compounds which lack a strong UV absorbing chromophore is really challenging. Despite the numerous analytical methods published, the demand for a simple, robust and cheap technique for their analysis still persists. Here, reversed phase (RP) liquid chromatography (LC) with capacitively coupled contactless conductivity detection (C(4)D) was explored for the first time as a possible method for separation and detection of various aminoglycoside (AMG) antibiotics which were taken as typical test compounds: tobramycin (TOB), spectinomycin, streptomycin, amikacin, kanamycin A and kanamycin B. C(4)D was performed using a commercially available as well as a laboratory made cell. As ion-pairing reagents (IPR) four perfluorinated carboxylic acids were used: pentafluoropropionic acid, heptafluorobutyric acid, nonafluoropentanoic acid (NFPA) and pentadecafluorooctanoic acid (PDFOA). 0.125 mM NFPA-acetonitrile (ACN) (90:10) or 0.125 mM PDFOA-ACN (70:30) as mobile phases were suitable to detect TOB with reasonable retention times. However, NFPA was preferred for practical reasons. Its applicable concentration range in the mobile phase was strongly restricted by loss of chromatographic performance at lower levels and excessive background conductivity at higher levels. Overall repeatability and robustness of the method were rather poor which was explained by the relatively low IPR levels. Selectivity between the tested AMGs was mainly influenced by the number of protonated amino groups per molecule making it impossible to separate compounds of equal net charges. Problems encountered with gradient elution, hydrophilic interaction liquid chromatography (HILIC) and separation at high pH without IPRs are also discussed.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Acetic acid-12C2, 99.9 atom % 12C
Sigma-Aldrich
Acetic acid, natural, ≥99.5%, FG
SAFC
L-Threonine
Sigma-Aldrich
L-Threonine, BioXtra, ≥99.5% (NT)
Sigma-Aldrich
L-Threonine, reagent grade, ≥98% (HPLC)
Sigma-Aldrich
Sodium hydroxide solution, 1.0 N, BioReagent, suitable for cell culture
Sigma-Aldrich
Sodium hydroxide solution, BioUltra, Molecular Biology, 10 M in H2O
Sigma-Aldrich
Sodium hydroxide, BioUltra, suitable for luminescence, ≥98.0% (T), pellets
Sigma-Aldrich
Acetic acid, suitable for luminescence, BioUltra, ≥99.5% (GC)
Sigma-Aldrich
3-Ethyl-2,4-pentanedione, mixture of tautomers, 98%
Sigma-Aldrich
Pentafluoropropionic acid, 97%
Sigma-Aldrich
Perfluorooctanoic acid, 95%
Sigma-Aldrich
L-Threonine, from non-animal source, meets EP, JP, USP testing specifications, suitable for cell culture, 99.0-101.0%
Sigma-Aldrich
Acetic acid, ≥99.5%, FCC, FG
Sigma-Aldrich
Sodium hydroxide, ultra dry, powder or crystals, 99.99% trace metals basis
Sigma-Aldrich
Sodium hydroxide-16O solution, 20 wt. % in H216O, 99.9 atom % 16O
Sigma-Aldrich
DL-Methionine, 99%, FCC, FG
Sigma-Aldrich
DL-Leucine, ≥99% (HPLC)
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Sigma-Aldrich
Heptafluorobutyric acid, 98%
Sigma-Aldrich
Heptafluorobutyric acid, ≥99.0% (GC)
Sigma-Aldrich
DL-Methionine, BioReagent, suitable for cell culture, suitable for insect cell culture, ≥99%
Sigma-Aldrich
DL-Valine, ReagentPlus®, ≥99.0% (NT)
Sigma-Aldrich
DL-Methionine, ≥99%
Sigma-Aldrich
Acetonitrile, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
Perfluoropentanoic acid, 97%
Sigma-Aldrich
DL-Valine, ≥97%
Sigma-Aldrich
Acetonitrile, Preparateur, ≥99.9% (GC), One-time steel-plastic (SP) drum