跳转至内容
Merck
CN

502219

Supelco

4-二甲胺基苯基偶氮苯磺酰氯

别名:

4-(二甲氨基)偶氮苯-4′-磺酰氯, 4-(N,N-二甲基氨基)偶氮苯-4′-磺酸氯, 4-二甲胺基苯基偶氮苯磺酰氯, DABS-Cl

登录查看公司和协议定价

关于此项目

线性分子式:
(CH3)2NC6H4N=NC6H4SO2Cl
CAS Number:
分子量:
323.80
Beilstein:
3064095
EC 号:
MDL编号:
UNSPSC代码:
12352200
PubChem化学物质编号:
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助

等级

derivatization grade ((HPLC))

表单

solid

包装

pkg of 500 mg

mp

185 °C (dec.) (lit.)

储存温度

room temp

SMILES字符串

CN(C)c1ccc(cc1)\N=N\c2ccc(cc2)S(Cl)(=O)=O

InChI

1S/C14H14ClN3O2S/c1-18(2)13-7-3-11(4-8-13)16-17-12-5-9-14(10-6-12)21(15,19)20/h3-10H,1-2H3/b17-16+

InChI key

VTVWTPGLLAELLI-WUKNDPDISA-N

正在寻找类似产品? 访问 产品对比指南

一般描述

丹磺酰氯(4-二甲基氨基偶氮苯-4′-磺酰氯)是用于HPLC的衍生化氨基酸的发色标记试剂。它可与所有氨基酸自由地发生反应,形成丹磺酰氨基酸,这些氨基酸具有光稳定性,可以在薄层色谱板上观察到。

其他说明

探索最适于 HPLCLC-MS 分析的 LiChropur 试剂

象形图

Corrosion

警示用语:

Danger

危险声明

危险分类

Skin Corr. 1B

储存分类代码

8A - Combustible corrosive hazardous materials

WGK

WGK 3

闪点(°F)

Not applicable

闪点(°C)

Not applicable

个人防护装备

Eyeshields, Faceshields, Gloves, type P3 (EN 143) respirator cartridges


历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Jansen, E.H.J., et al.
Journal of Chromatography A, 553 (1991)
Chromophoric labeling of amino acids with 4-dimethylaminoazobenzene-4'-sulfonyl chloride.
J K Lin and J Y Chang.
Analytical Chemistry, 47 (9), 1634-1638 (1975)
Reversed-phase high-performance liquid chromatography separation of dimethylaminoazobenzene sulfonyl- and dimethylaminoazobenzene thiohydantoin-amino acid derivatives for amino acid analysis and microsequencing studies at the picomole level.
v
Analytical Biochemistry, 178(1), 107-117 (1989)
A Zaramella et al.
Journal of combinatorial chemistry, 3(5), 410-420 (2001-09-11)
The presence of dansyl or dabsyl chromogenic moieties in a solid-phase analytical construct, an assembly of linkers/spacers/sensitizers for improving analytical characterization, allows the accurate estimation of products from solid-phase synthesis by UV detection during liquid chromatography-mass spectrometry analysis in the
Z Wu et al.
Journal of chromatography. A, 773(1-2), 291-298 (1997-06-27)
Forward-scattering four-wave mixing is demonstrated as a sensitive absorbance detection method for capillary electrophoresis, using an argon ion laser operating at 457.9 nm. Since this four-wave mixing laser technique utilizes only two input laser beams, it offers important advantages, including

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系客户支持