跳转至内容
Merck
CN
  • Retrievability of implant-supported crowns when using three different cements: a controlled clinical trial.

Retrievability of implant-supported crowns when using three different cements: a controlled clinical trial.

The International journal of prosthodontics (2015-01-15)
Andreas Worni, Hadi Gholami, Laurent Marchand, Joannis Katsoulis, Regina Mericske-Stern, Norbert Enkling
摘要

The purpose of this study was to analyze the removal of implant-supported crowns retained by three different cements using an air-accelerated crown remover and to evaluate the patients' response to the procedure. This controlled clinical trial was conducted with 21 patients (10 women, 11 men; mean age: 51 ± 10.2 years) who had received a total of 74 implants (all placed in the posterior zone of the mandible). Four months after implant surgery, the crowns were cemented on standard titanium abutments of different heights. Three different cements (two temporary: Harvard TEMP and Improv; and one definitive: Durelon) were used and randomly assigned to the patients. Eight months later, one blinded investigator removed all crowns. The number of activations of the instrument (CORONAflex, KaVo) required for crown removal was recorded. The patients completed a questionnaire retrospectively to determine the impact of the procedure and to gauge their subjective perception. A linear regression model and descriptive statistics were used for data analysis. All crowns could be retrieved without any technical complications or damage. Both abutment height (P = .019) and cement type (P = .004) had a significant effect on the number of activations, but the type of cement was more important. An increased total number of activations had no or only a weak correlation to the patients' perception of concussion, noise, pain, and unwillingness to use the device. Cemented implant crowns can be removed, and the application of an air-accelerated device is a practicable method. A type of cement with appropriate retention force has to be selected. The impact on the patients' subjective perception should be taken into account.

材料
Product Number
品牌
产品描述

Sigma-Aldrich
磷酸锌, 99.998% trace metals basis
钛, mesh, 100x100mm, nominal aperture 0.19mm, wire diameter 0.23mm, 60x60 wires/inch, open area 20%, twill weave
Sigma-Aldrich
钛, wire, diam. 0.25 mm, 99.7% trace metals basis
钛, mesh, 100x100mm, nominal aperture 4.3mm, wire diameter 1.5mm, 4.4x4.4 wires/inch, open area 94%, platinized diamond mesh
Sigma-Aldrich
钛, foil, thickness 2.0 mm, 99.7% trace metals basis
钛, rod, 10mm, diameter 50mm, 99.99+%
钛, rod, 25mm, diameter 50mm, 99.99+%
Sigma-Aldrich
钛, wire, diam. 0.5 mm, 99.99% trace metals basis
钛, wire, straight, 1000mm, diameter 1.0mm, as drawn, 99.6+%
钛, tube, 200mm, outside diameter 2.03mm, inside diameter 1.55mm, wall thickness 0.24mm, annealed, 99.6+%
钛, wire reel, 2m, diameter 1.0mm, as drawn, 99.99+%
钛, rod, 200mm, diameter 2mm, as drawn, 99.99+%
钛, wire reel, 25m, diameter 0.20mm, annealed, 99.6+%
钛, rod, 1000mm, diameter 2mm, annealed, 99.6+%
钛, rod, 1000mm, diameter 1.5mm, annealed, 99.6+%
钛, wire reel, 1m, diameter 0.5mm, as drawn, 99.99+%
钛, wire reel, 0.5m, diameter 0.25mm, as drawn, 99.99+%
钛, rod, 100mm, diameter 30mm, annealed, 99.6+%
钛, tube, 500mm, outside diameter 9.5mm, inside diameter 8.2mm, wall thickness 0.65mm, annealed, 99.6+%
钛, rod, 100mm, diameter 2mm, annealed, 99.6+%
钛, tube, 100mm, outside diameter 3.0mm, inside diameter 1.5mm, wall thickness 0.75mm, annealed, 99.6+%
钛, rod, 500mm, diameter 5mm, annealed, 99.6+%
钛, wire reel, 1m, diameter 0.25mm, as drawn, 99.6+%
钛, tube, 1000mm, outside diameter 10mm, inside diameter 8mm, wall thickness 1.0mm, annealed, 99.6+%
钛, wire reel, 1m, diameter 0.25mm, annealed, 99.6+%
钛, rod, 100mm, diameter 10mm, annealed, 99.6+%
钛, rod, 100mm, diameter 5mm, annealed, 99.6+%
钛, rod, 200mm, diameter 1.5mm, annealed, 99.6+%
钛, tube, 1000mm, outside diameter 10.3mm, inside diameter 8.7mm, wall thickness 0.8mm, annealed, 99.6+%
钛, rod, 200mm, diameter 3.0mm, annealed, 99.6+%