Skip to Content
Merck
CN
  • A monoclonal antibody-based enzyme-linked immunosorbent assay of glycolithocholic acid sulfate in human urine for liver function test.

A monoclonal antibody-based enzyme-linked immunosorbent assay of glycolithocholic acid sulfate in human urine for liver function test.

Steroids (2002-09-17)
Norihiro Kobayashi, Hiroshi Katsumata, Yoshiaki Uto, Junichi Goto, Toshifumi Niwa, Koju Kobayashi, Yoshiaki Mizuuchi
ABSTRACT

Urinary levels of sulfated metabolites of lithocholic acid (LCA) are expected to be a useful index of liver function. Thus, a sensitive, specific, and feasible enzyme-linked immunosorbent assay (ELISA) of these sulfated LCA metabolites (LCA-Suls) should be established. A newly generated monoclonal antibody specific to glycolithocholic acid sulfate (glycine-amidated LCA-Sul (GLCA-Sul)) was immobilized on microtiter plates via a second antibody. A urine specimen and an alkaline phosphatase-labeled antigen were added to the plate, which was then incubated at room temperature for 3h. After this competitive reaction, bound enzyme activity was measured colorimetrically using p-nitrophenyl phosphate as a substrate. The detection limit for GLCA-Sul was 0.4 pg/assay. Nonamidated LCA-Sul and taurine-conjugated LCA-Sul showed 40 and 11% cross-reactivities, respectively, while 3-sulfates of cholic acid (CA; 0.02%), chenodeoxycholic acid (CDCA; 0.63%), and deoxycholic acid (DCA; 2.2%) exhibited very low cross-reactivities. Applicability of the ELISA system to clinical samples was well validated by parallelism, recovery test, and intra/inter-assay variance. Enzymatic deconjugation with bile acids sulfatase resulted in dramatically decreased urinary levels, supporting the specificity of the ELISA toward GLCA-Sul. The mean GLCA-Sul levels in early morning urine from healthy volunteers were 314 ng/mg Ucre (males: n=16) and 507 ng/mg Ucre (females: n=9). Patients with liver diseases, including chronic hepatitis (CH) and liver cirrhosis (LC) exhibited significantly higher values (mean 5222 ng/mg Ucre: n=21). The present 'monoclonal ELISA' is predicted to be useful as a novel noninvasive diagnostic tool for liver function and hepatobiliary diseases.

MATERIALS
Product Number
Brand
Product Description

Supelco
L-Aspartic acid, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
L-Aspartic acid, reagent grade, ≥98% (HPLC)
Sigma-Aldrich
Urea-12C, 99.9 atom % 12C
Sigma-Aldrich
Urea solution, 40 % (w/v) in H2O
SAFC
L-Aspartic acid
Millipore
Urea solution, suitable for microbiology, 40% in H2O
Supelco
Propylene glycol, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
2,3-Butanediol, 98%
Sigma-Aldrich
Linoleic acid, technical, 58-74% (GC)
Supelco
L-Aspartic acid, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Sigma-Aldrich
L-Aspartic acid, from non-animal source, meets EP, USP testing specifications, suitable for cell culture, 98.5-101.0%
Sigma-Aldrich
L-Aspartic acid, BioUltra, ≥99.5% (T)
Sigma-Aldrich
L-Aspartic acid, BioXtra, ≥99% (HPLC)
Sigma-Aldrich
Propylene glycol, ≥99.5% (GC), FCC, FG
Sigma-Aldrich
Propylene Glycol, meets USP testing specifications
Sigma-Aldrich
Urea solution, BioUltra, ~8 M in H2O
Supelco
Linoleic acid, analytical standard
Sigma-Aldrich
Linoleic acid, liquid, BioReagent, suitable for cell culture
Sigma-Aldrich
2,3-Butanediol, Vetec, reagent grade, 98%
Sigma-Aldrich
α-Linoleic acid, ≥98%
Sigma-Aldrich
1,2-Propanediol, tested according to Ph. Eur.
Sigma-Aldrich
1,2-Propanediol, meets analytical specification of Ph. Eur., BP, USP, ≥99.5%
Sigma-Aldrich
1,2-Propanediol, puriss. p.a., ACS reagent, ≥99.5% (GC)
Supelco
1,2-Propanediol, analytical standard
Sigma-Aldrich
1,2-Propanediol, ReagentPlus®, 99%
Sigma-Aldrich
1,2-Propanediol, ACS reagent, ≥99.5%
Sigma-Aldrich
Creatine, anhydrous
Supelco
Urea, 8 M (after reconstitution with 16 mL high purity water)
Sigma-Aldrich
Urea, puriss. p.a., ACS reagent, reag. Ph. Eur., ≥99%
Sigma-Aldrich
Urea, ACS reagent, 99.0-100.5%