  • Calculated and experimental chromatograms for distorted gradients and non-linear solvation strength retention models.

Calculated and experimental chromatograms for distorted gradients and non-linear solvation strength retention models.

Journal of chromatography. A (2014-07-08)
Fabrice Gritti, Georges Guiochon
ABSTRACT

Computer calculations of gradient chromatograms were performed by taking into account the adsorption behavior of the strong eluent in RPLC and the true Henry constant of the analytes. This improves the accuracy of classical gradient calculations, which all assume no affinity of the eluent modifier for the stationary phase and that the linear solvation strength model (LSSM) applies. The excess adsorption isotherm of acetonitrile with respect to water was measured by the minor disturbance method onto a Symmetry-C₁₈ RPLC adsorbent. The variations of the Henry constants of a nine compound mixture with the volume fraction of acetonitrile in the aqueous mobile phase were measured. The equilibrium dispersive model of chromatography combined with orthogonal collocation on finite elements was used to calculate chromatograms of the sample mixture for four gradient times decreasing from 25 to 1 min. The results predict a loss of resolution for the less retained analytes when the gradient times becomes smaller than 4 min. They also predict that this behavior can be eliminated when applying a quadratic gradient profile rather than a classical linear gradient. The predictions were validated by the agreement between the calculated and experimental chromatograms.

MATERIALS
Product Number
Brand
Product Description

Supelco
Phenol solution, 5000 μg/mL in methanol, certified reference material
Sigma-Aldrich
Phenol, unstabilized, ReagentPlus®, ≥99%
Sigma-Aldrich
Water, PCR Reagent
Sigma-Aldrich
Water, Nuclease-Free Water, for Molecular Biology
Sigma-Aldrich
E-Toxate Water, endotoxin, free
Sigma-Aldrich
Phenol solution, Equilibrated with 10 mM Tris HCl, pH 8.0, 1 mM EDTA, BioReagent, for molecular biology
Sigma-Aldrich
Water, sterile-filtered, BioReagent, suitable for cell culture
Sigma-Aldrich
Phenol, BioXtra, ≥99.5% (GC)
Sigma-Aldrich
Water, for embryo transfer, sterile-filtered, BioXtra, suitable for mouse embryo cell culture
Sigma-Aldrich
Phenol solution, Saturated with 0.1 M citrate buffer, pH 4.3 ± 0.2, BioReagent, for molecular biology
Sigma-Aldrich
Phenol, for molecular biology
Sigma-Aldrich
Liquified Phenol, ≥89.0%
Sigma-Aldrich
Phenol, puriss., ≥99.5% (GC), meets analytical specification of Ph. Eur., BP, USP, crystalline (detached)
Sigma-Aldrich
Phenol, puriss., meets analytical specification of Ph. Eur., BP, USP, 99.5-100.5% (GC)
Supelco
Phenol, PESTANAL®, analytical standard
Sigma-Aldrich
Water, tested according to Ph. Eur.
Sigma-Aldrich
Water, for molecular biology, sterile filtered
Sigma-Aldrich
Phenol, puriss. p.a., ACS reagent, reag. Ph. Eur., 99.0-100.5%
Sigma-Aldrich
Phenol, ≥99%
Supelco
Water, for HPCE, for luminescence, suitable for UV/Vis spectroscopy
Supelco
Phenol solution, 100 μg/mL in acetonitrile, PESTANAL®, analytical standard
Sigma-Aldrich
Phenol, BioUltra, for molecular biology, ≥99.5% (GC)
Sigma-Aldrich
Water, deuterium-depleted, ≤1 ppm (Deuterium oxide)
Sigma-Aldrich
Phenol, unstabilized, purified by redistillation, ≥99%
Sigma-Aldrich
Phenol, ≥96.0% (calc. on dry substance, T)
Sigma-Aldrich
Water, for cell biology, sterile ultrafiltered
Sigma-Aldrich
Phenol, BioUltra, for molecular biology, TE-saturated, ~73% (T)
Supelco
Phenol, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Water, ACS reagent, for ultratrace analysis
Sigma-Aldrich
Water, BioPerformance Certified