EP6731000322
Eppendorf® CellXpert® C170i CO2 Incubator
water/humidity monitoring, Handle on left, inner door non-segmented, AC/DC input 220—240 V, 50—60 Hz, UK plug
别名:
Heaters
包装
pack of 1 ea
制造商/商品名称
Eppendorf® 6731000322
参数
±4-50 °C ambient temp. range
宽度 × 深度 × 高度
53.9 cm (21.2 in.) × 44.5 cm (14.5 in.) × 69.2 cm (27.3 in.)
platform W × depth
52.2 cm (20.6 in.) × 42.8 cm (16.9 in.)
体积
167 L
正在寻找类似产品? 访问 产品对比指南
一般描述
特点和优势
- 180 °C high temperature disinfection with clear step-by-step instructions on the screen and implementation protocol for standardized procedures that can be downloaded
- The few interior parts can be removed
- from the incubator in 40 s and quickly wiped down
- No hiding place for Contamination and quick to clean: Smooth incubator chamber with no bumps
- Fanless design
- No non-sterilizable HEPA filters with fan attachment that can be potential sources of contamination
- Options for copper trim and partitioned interior doors for added protection
法律信息
储存分类代码
11 - Combustible Solids
法规信息
相关内容
Exosomes derived from mesenchymal stem cells (MSC) are a new alternative to restore tissues and organs, avoiding the limitations associated with stem cell therapy. MSC-derived exosomes are involved in MSC’s paracrine functions related to cell-to-cell communications and tissue reconstruction, leading to cell self-renewal and differentiation. Despite the benefits of stem cell use, there are limitations, including the large-scale production of cells that mimic physiological conditions. Therefore, increasing the mass production of exosomes in a controlled environment is the necessary next step. In this study, we used a combination of SciVario® twin bioreactor control system and BioBLU® 1c Single-Use Vessels as a model for large scale exosome production in bioreactors. The SciVario twin is a future-proof bioreactor control system developed by Eppendorf. Following the agile development principle, the controller was designed with a maximum working volume of 3.7 L at launch, but the flexibility of the system allows for future hard- and software updates using vessels as large as 40 L. In this application note, we monitored and analyzed the metabolites derived from the human induced Pluripotent Stem Cells (hiPSC) as well as cell adhesion and morphology, suggesting that we obtained an excellent physiological environment over time. Furthermore, we isolated, purified and quantified (by CD63 ELISA kit) the exosomes produced from MSC.
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系客户支持