跳转至内容
Merck
CN

G006323

GC Analysis of PCBs in Cod Liver Oil (Spiked) on SLB®-5ms after SPE using Supelclean EZ-POP NP and Supelclean LC-Si

application for SPE, suitable for GC

登录查看公司和协议定价

选择尺寸


技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助

技术

gas chromatography (GC): suitable
solid phase extraction (SPE): suitable

试验参数

sample preparation: SPE (Solid Phase Extraction)
sample/matrix: cod liver oil spiked with PCBs (at 10 ng/g)
SPE tube/cartridge: Supelclean EZ-POP NP, 12 mL, Pk 20 (54341-U)
condition: 10 mL acetone, 10 min dry at 20" mercury
sample addition: 0.5 g sample, weighed directly on cartridge
elution: 15 mL acetonitrile
eluate post-treatment: back extract acetonitrile eluent with 2 x 10 mL portions of hexane, evaporate hexane extract to approximately 1 mL at 40 ºC under nitrogen
SPE tube/cartridge: Supelclean LC-Si, 100 mg/1 mL (504041)
condition: 4 mL acetone, 10 min dry at 20" mercury, then 4 mL hexane
sample addition: 1 mL of resulting extract from above
elution: 5 mL hexane
eluate post-treatment: evaporate to 1 mL at 40 ºC under nitrogen
column: SLB-5ms 20m x 0.18mm, 0.18 μm (28564-U)
oven: 75 °C (1 min), 12 °C/min to 340 °C (20 min)
inj. temp.: 250 °C
detector: μECD, 340 °C
carrier gas: hydrogen, 1.2 mL/min
injection: 1 μL, splitless (0.75 min)
liner: 4 mm I.D., split/splitless type, wool packed single taper FocusLiner design

适用性

application for SPE

应用

food and beverages

分析说明

PCBs are lipophilic and they have a tendency to bioaccumulate and, through bioaccumulation, may pose a risk to humans. When PCB-containing substances are cleaned or dumped into rivers or oceans, PCBs may find their way into aquatic lifeforms such as fish. Fish oil, which is high in levels of the beneficial fatty acids EPA and DHA, is a popular nutritional supplement. Due to the health risk of exposure to PCBs, fish oil is often analyzed for the presence of these compounds to ensure its safety. In this application, a new extraction/cleanup method was developed for PCBs from pure cod liver oil (which was spiked with PCBs) using the EZ-POP NP SPE cartridge.

法律信息

FocusLiner is a trademark of SGE Analytical Science Pty Ltd.
SLB is a registered trademark of Merck KGaA, Darmstadt, Germany
Supelclean is a trademark of Sigma-Aldrich Co. LLC

分析物

说明

    2,4,4′,-Trichlorobiphenyl (No. 28)
    2,2′,5,5′-Tetrachlorobiphenyl (No. 52)
    2,2′,4,5,5′-Pentachlorobiphenyl (No. 101)
    3,4,4′,5-Tetrachlorobiphenyl (No.81)
    3,3′,4,4′-Tetrachlorobiphenyl (No. 77)
    2′,3,4,4′,5-Pentachlorobiphenyl (No. 123)
    2,3′,4,4′,5-Pentachlorobiphenyl (No. 118)
    2,3,4,4′,5-Pentachlorobiphenyl (No. 114)
    2,2′,4,4′,5,5′-Hexachlorobiphenyl (No. 153)
    2,3,3′,4,4′-Pentachlorobiphenyl (No. 105)
    2,2′,3,4,4′,5′-Hexachlorobiphenyl (No. 138)
    3,3′,4,4′,5-Pentachlorobiphenyl (No. 126)
    2,3′,4,4′,5,5′-Hexachlorobiphenyl (No. 167)
    2,3,3′,4,4′,5-Hexachlorobiphenyl (No. 156)
    2,3,3′,4,4′,5′-Hexachlorobiphenyl (No. 157)
    2,2′,3,4,4′,5,5′-Heptachlorobipheny (No. 180)
    3,3′,4,4′,5,5′-Hexachlorobiphenyl (No. 169)
    2,3,3′,4,4′,5,5′-Heptachlorobiphenyl (No. 189)
    2,2′,3,3′,4,4′,5′5′,6,6′-Decachlorobiphenyl (No. 209)