product line
ProteoMass™
CofA
current certificate can be downloaded
packaging
pkg of 1 × 10 mL
storage condition
protect from light
concentration
(varied conc.)
technique(s)
mass spectrometry (MS): suitable
format
multi-component solution
shipped in
dry ice
storage temp.
−20°C
Quality Level
正在寻找类似产品? 访问 产品对比指南
General description
The ProteoMass ESI Calibration Kit for LTQ based Hybrids, positive ion mode calibration solution, enables calibration of Thermo Scientific hybrid instruments equipped with ESI source in positive ion mode. It covers a mass range from m/z 138 to m/z 1822, and is therefore usable for calibrations between m/z 50 and 2000.
Application
ProteoMass™ LTQ/FT-hybrid ESI Pos. mode cal mix has been used as a calibration standard for the mass spectrometric analysis of serum samples of patients affected by mugwort pollen allergy induced by pollen extract of Artemisia vulgaris.
Features and Benefits
Discover the Advantages for Yourself!
- Ready-to-use
- Developed and qualified specifically for use with the LTQ based Thermo Scientific hybrid instruments (LTQ FT, LTQ FT Ultra, and LTQ Orbitrap series) with ESI source and Thermo Scientific Exactive
- Conveniently packaged, freeing you from time consuming mixing and dilution steps, allowing you to focus on the acquistion of quality data
Legal Information
ProteoMass is a trademark of Sigma-Aldrich Co. LLC
signalword
Danger
Hazard Classifications
Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Eye Irrit. 2 - Flam. Liq. 2 - STOT SE 1
target_organs
Eyes,Central nervous system
存储类别
3 - Flammable liquids
wgk
WGK 2
flash_point_f
42.1 °F - closed cup
flash_point_c
5.6 °C - closed cup
法规信息
监管及禁止进口产品
此项目有
Robert J Strife et al.
Rapid communications in mass spectrometry : RCM, 24(11), 1497-1501 (2010-05-21)
Kendrick Mass Mapping of complex sample compositions, via data derived by Fourier transform ion cyclotron resonance mass spectrometry (FTICRMS) at 1,000,000 resolution, is becoming more common. The Orbitrap mass spectrometer (Fourier Transform Axially Harmonic Orbital Trapping) also uses FT methods
Adam P Bateman et al.
Analytical chemistry, 82(19), 8010-8016 (2010-09-03)
This work demonstrates the utility of a particle-into-liquid sampler (PILS), a technique traditionally used for identification of inorganic ions present in ambient or laboratory aerosols, for the analysis of water-soluble organic aerosol (OA) using high-resolution electrospray ionization mass spectrometry (HR-ESI-MS).
Toine F H Bovee et al.
Food additives & contaminants. Part A, Chemistry, analysis, control, exposure & risk assessment, 33(5), 749-759 (2016-04-20)
In 2013 the Dutch authorities issued a warning against a dietary supplement that was linked to 11 reported adverse reactions, including heart problems and in one case even a cardiac arrest. In the UK a 20-year-old woman, said to have
Hypoallergenic acid-sensitive modification preserves major mugwort allergen fold and delivers full repertoire of MHC class II-binding peptides during endolysosomal degradation
Stanic-Vucinic D, et al.
Royal Society of Chemistry Advances, 91(6), 88216-88228 (2016)
Adam P Bateman et al.
Physical chemistry chemical physics : PCCP, 13(26), 12199-12212 (2011-05-28)
The effect of UV irradiation on the molecular composition of aqueous extracts of secondary organic aerosol (SOA) was investigated. SOA was prepared by the dark reaction of ozone and d-limonene at 0.05-1 ppm precursor concentrations and collected with a particle-into-liquid
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系客户支持