  • Analysis of extracellular metabolome by HS-SPME/GC-MS: Optimization and application in a pilot study to evaluate galactosamine-induced hepatotoxicity.

Analysis of extracellular metabolome by HS-SPME/GC-MS: Optimization and application in a pilot study to evaluate galactosamine-induced hepatotoxicity.

Toxicology letters (2018-06-01)
Ana Margarida Araújo, Nathalie Moreira, Ana Rita Lima, Maria de Lourdes Bastos, Félix Carvalho, Márcia Carvalho, Paula Guedes de Pinho
摘要

Two methods based on headspace solid-phase microextraction (HS-SPME) coupled to gas chromatography-mass spectrometry (GC-MS) were developed to study in vitro the volatile exometabolome, which were then further tested in a pilot study to evaluate galactosamine-induced hepatotoxicity. The analysis of volatile organic compounds (VOCs) was carried out directly in the headspace of the cell culture medium, while some other volatile organic compounds such as volatile carbonyl compounds (VCCs) (aldehydes and ketones) were determined in the headspace of the cell culture medium after a previous derivatization step with O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine hydrochloride (PFBHA). Fiber selection was performed using a univariate mode, whereas a central composite design (CCD) was used in the optimization of several other parameters that affect the extraction conditions. VOCs showed optimal extraction results using a DVB/CAR/PDMS fiber, by adding 0.43 g of NaCl to a sample volume of 2 mL and allowing the sample to equilibrate for 10 min at 45 °C with a subsequent extraction for 39 min at the same temperature. For VCCs, the best extraction response was achieved after in-solution (2 mL) derivatization with 0.94 g L-1 of PFBHA (final concentration), followed by an incubation period of 6 min and an extraction time of 37 min at 53 °C, using a PDMS/DVB fiber. The applicability of both optimized methods was then tested, through a untargeted study, on cell culture medium samples obtained from primary mouse hepatocytes (PMH) exposed to three low concentrations (LC01, LC10 and LC30) of the well-known hepatotoxic agent galactosamine (GalN). The results obtained by both methods showed that volatile compounds from GalN exposed cells are separated from controls in a concentration-dependent manner. Several volatile compounds, namely aldehydes, ketones and alcohols, suffered significant alterations, suggesting that GalN induces marked metabolic alterations in cells even at low, non-toxic concentrations. Although preliminary, this metabolomics approach proved its potential to be used in future studies to evaluate toxicity of different xenobiotics.

材料
产品编号
品牌
产品描述

Sigma-Aldrich
Triton X-100, laboratory grade
Supelco
SPME萃取头组件, 50/30µm DVB/CAR/PDMS, StableFlex (1 cm), needle size 23 ga, Autosampler, pk of 3, plain gray hub
Supelco
SPME萃取头组件, 50/30µm DVB/CAR/PDMS, StableFlex (2cm), needle size 24 ga, Autosampler, pk of 3, notched gray hub
Supelco
SPME萃取头组件, 50/30µm DVB/CAR/PDMS, StableFlex (1cm), needle size 24 ga, Manual Holder, pk of 3, plain gray hub
Supelco
SPME萃取头组件, 50/30µm DVB/CAR/PDMS, StableFlex (2cm), needle size 23 ga, Autosampler, pk of 3, notched gray hub
Supelco
SPME 纤维组件聚二甲基硅氧烷 (PDMS), 100 μm PDMS, Fused Silica (1 cm), needle size 23 ga, Autosampler, pk of 3, red hub
Supelco
SPME萃取头组件, 50/30µm DVB/CAR/PDMS, StableFlex (1 cm), needle size 24 ga, Autosampler, pk of 3, plain gray hub
Supelco
SPME 纤维组件聚二甲基硅氧烷 (PDMS), 100 μm PDMS, Fused Silica (1 cm), needle size 24 ga, Manual Holder, pk of 3, red hub
Sigma-Aldrich
聚二甲基硅氧烷, viscosity 1.0 cSt (25 °C)
Supelco
SPME固相微萃取萃取头 Carboxen/聚二甲基硅氧烷 (CAR/PDMS), 75 μm CAR/PDMS, Fused Silica (1 cm), needle size 24 ga, Manual Holder, pk of 3, black hub
Sigma-Aldrich
D-(+)-半乳糖胺 盐酸盐, ≥99% (HPLC)
Supelco
SPME 纤维组件聚二甲基硅氧烷 (PDMS), 100 μm PDMS, Fused Silica (1 cm), needle size 24 ga, Autosampler, pk of 3, red hub
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), 65 μm PDMS/DVB, Fused Silica (1 cm), needle size 24 ga, Manual Holder, pk of 3, blue hub
Supelco
SPME固相微萃取萃取头 Carboxen/聚二甲基硅氧烷 (CAR/PDMS), 75 μm CAR/PDMS, Fused Silica (1 cm), needle size 24 ga, Autosampler, pk of 3, black hub
Supelco
SPME固相微萃取萃取头 Carboxen/聚二甲基硅氧烷 (CAR/PDMS), 85 μm CAR/PDMS, StableFlex (1 cm), needle size 23 ga, Autosampler, pk of 3, light blue hub
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), 65 μm PDMS/DVB, StableFlex (1 cm), needle size 23 ga, Autosampler, pk of 3, pink hub
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), 65 μm PDMS/DVB, Fused Silica (1 cm), needle size 24 ga, Autosampler, pk of 3, blue hub
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), 65 μm PDMS/DVB, StableFlex (1 cm), needle size 24 ga, Manual Holder, pk of 3, pink hub
Supelco
SPME固相微萃取萃取头 Carboxen/聚二甲基硅氧烷 (CAR/PDMS), 85 μm CAR/PDMS, StableFlex (1 cm), needle size 24 ga, Manual Holder, pk of 3, light blue hub
Supelco
聚丙烯酸酯 (PA) 固相微萃取萃取头, 85 μm Polyacrylate, Fused Silica (1 cm), needle size 24 ga, Autosampler, pk of 3, white hub
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), 65 μm PDMS/DVB, StableFlex (1 cm), needle size 24 ga, Autosampler, pk of 3, pink hub
Supelco
固相微萃取便携式现场采样器, coating PDMS/DVB
Supelco
SPME固相微萃取萃取头 Carboxen/聚二甲基硅氧烷 (CAR/PDMS), 85 μm CAR/PDMS, StableFlex (1 cm), needle size 24 ga, Autosampler, pk of 3, light blue hub
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), 65 μm PDMS/DVB, Fused Silica (1 cm), needle size 23 ga, Manual Holder, pk of 3, blue hub
Supelco
聚丙烯酸酯 (PA) 固相微萃取萃取头, 85 μm Polyacrylate, Fused Silica (1 cm), needle size 23 ga, Autosampler, pk of 3, white hub
Supelco
固相微萃取便携式现场采样器, coating PDMS
Supelco
固相微萃取 StableFlex 萃取头组合套件, Assortment, StableFlex (1 cm), needle size 24 ga, Manual Holder, pk of 4
Supelco
SPME固相微萃取萃取头 Carboxen/聚二甲基硅氧烷 (CAR/PDMS), 75 μm CAR/PDMS, Fused Silica (1 cm), needle size 23 ga, Autosampler, pk of 3, black hub
Supelco
SPME 纤维组件聚二甲基硅氧烷 (PDMS), 100 μm PDMS, Fused Silica (1 cm), needle size 23 ga, Manual Holder, pk of 3, red hub
Supelco
固相微萃取 StableFlex 萃取头组合套件, Assortment, StableFlex (1 cm), needle size 23 ga, Autosampler, pk of 4