Merck
CN
  • Determination of creatine and guanidinoacetate by GC-MS: study of their stability in urine at different temperatures.

Determination of creatine and guanidinoacetate by GC-MS: study of their stability in urine at different temperatures.

Clinical biochemistry (2008-11-11)
José Angel Prieto, Fernando Andrade, Sergio Martín, Pablo Sanjurjo, Javier Elorz, Luís Aldámiz-Echevarría
摘要

Evaluation of a GC-MS method using N-tert-butyldimethylsilyl-N-methyltrifluoroacetamide (MTBSTFA) as the silylating agent for GC-MS. Study of the stability of creatine and guanidinoacetate in urine. 22 urines were kept at RT, 4 degrees C and -30 degrees C for 15 days. MTBSTFA produces a single chromatographic peak in contrast with other derivatizing agents. Creatine concentration increases at room temperature (326% on average), and at 4 degrees C (75%). However, detection decreases after freezing (-37%). Guanidinoacetate is stable, but decreases after freezing (-37%). Sonication before analysis is crucial to obtain repetitive results. A modified GC-MS method has been validated and the conditions for preservation of the urine have been established.

材料
货号
品牌
产品描述

Sigma-Aldrich
N --丁基二甲基硅基- N -甲基三氟乙酰胺, >97%
Sigma-Aldrich
N-叔丁基二甲基甲硅烷基-N-甲基三氟乙酰胺,含 1% 叔丁基二甲基氯硅烷, ≥95%
Supelco
MTBSTFA(含 1%t-BDMCS), ampule of 5 × 1 mL, (with 1% t-BDMCS), analytical standard, Cerilliant®