Merck
CN
  • Acid-soluble internal capsules for closed-face cassette elemental sampling and analysis of workplace air.

Acid-soluble internal capsules for closed-face cassette elemental sampling and analysis of workplace air.

Journal of occupational and environmental hygiene (2013-04-04)
Martin Harper, Kevin Ashley
摘要

Airborne particles that are collected using closed-face filter cassettes (CFCs), which are used widely in the sampling of workplace aerosols, can deposit in places other than on the filter and thereby may not be included in the ensuing analysis. A technique for ensuring that internal non-filter deposits are included in the analysis is to collect airborne particles within an acid-soluble internal capsule that, following sampling, can be dissolved along with the filter for subsequent elemental analysis. An interlaboratory study (ILS) was carried out to evaluate the use of cellulosic CFC capsule inserts for their suitability in the determination of trace elements in airborne samples. The ILS was performed in accordance with an applicable ASTM International standard practice, ASTM E691, which describes statistical procedures for investigating interlaboratory precision. Performance evaluation materials consisted of prototype cellulose acetate capsules attached to mixed-cellulose ester filters. Batches of capsules were dosed with Pb-containing materials (standard aqueous solutions, and certified reference material soil and paint). Also, aerosol samples containing nine target analyte elements (As, Cd, Co, Cr, Cu, Fe, Pb, Mn, and Ni) were generated using a multiport sampler; various concentrations and sampling times were employed to yield samples fortified at desired loading levels. Triplicates of spiked capsules at three different loadings were conveyed to each volunteer laboratory; loading levels were unknown to the participants. The laboratories were asked to prepare the samples by acid dissolution and to analyze aliquots of extracted samples by atomic spectrometry in accordance with applicable ASTM International Standards. Participants were asked to report their results in units of μg of each target element per sample. For the elements investigated, inter-laboratory precision and recovery estimates from the participating laboratories demonstrated the utility of the cellulosic capsule inserts for the measurement of sampled trace elements.

材料
货号
品牌
产品描述

Sigma-Aldrich
纤维素, microcrystalline, powder, 20 μm
Sigma-Aldrich
纤维素, fibers, (medium)
Sigma-Aldrich
纤维素, microcrystalline, powder
Supelco
Avicel® PH-101, ~50 μm particle size
Sigma-Aldrich
醋酸纤维素, average Mn ~30,000 by GPC
Sigma-Aldrich
Sigmacell 纤维素, Type 20, 20 μm
Sigma-Aldrich
醋酸纤维素, average Mn ~50,000 by GPC
Sigma-Aldrich
α纤维素, powder
Sigma-Aldrich
Avicel® PH-101, tested according to Ph. Eur.
Supelco
纤维素, powder, for column chromatography
Sigma-Aldrich
纤维素, colloidal, microcrystalline
Sigma-Aldrich
Sigmacell 纤维素, Type 101, Highly purified, fibers
Sigma-Aldrich
Sigmacell 纤维素, Type 50, 50 μm
Supelco
纤维素, DS-0, powder, suitable for thin layer chromatography (TLC)
Sigma-Aldrich
α纤维素, BioReagent, suitable for insect cell culture
Supelco
纤维素, acid washed, powder, for column chromatography
Supelco
纤维素, DFS-0, microcrystalline, suitable for thin layer chromatography (TLC)
Supelco
纤维素, acid washed, from spruce, for column chromatography