  • A respiration-metabolism chamber system and a GC-MS method developed for studying exhalation of perfluorobutane in rats after intravenous injection of the ultrasound contrast agent Sonazoid.

A respiration-metabolism chamber system and a GC-MS method developed for studying exhalation of perfluorobutane in rats after intravenous injection of the ultrasound contrast agent Sonazoid.

Journal of pharmaceutical and biomedical analysis (2005-06-21)
Steinar Uran, Kristin Landmark, Per Trygve Normann, Petter-Arnt Hals, Kim Gunnar Toft, Tore Skotland
摘要

Sonazoid is a new contrast agent for ultrasound imaging comprising an aqueous suspension of lipid-stabilised perfluorobutane (PFB) gas microbubbles. A respiration-metabolism chamber system was developed to collect exhaled air following intravenous administration of Sonazoid to rats. Analysis of PFB in the exhaled rat air was performed using a modified version of an earlier published method for blood samples, i.e. an automatic headspace gas chromatographic mass spectrometric (GC-MS) method using electron impact ionisation. The calibration standards were PFB diluted in air (2.5-1800 pg/ml). Perfluoropentane (PFP) was used as an internal standard and the MS detector was set to single ion monitoring of the base fragment ions of PFB (m/z 69 and 119) and PFP (m/z 69). The calibration curve, made by plotting the peak area ratios of PFB (m/z 69) to PFP (m/z 69) against the theoretical concentration of PFB, was fitted to a linear equation with weighting 1/y2 and found to be reproducible. The lower limit of quantification (LLOQ) was 2.5 pg PFB/ml. The between-day variation of the method was below 2.6% relative standard deviation (R.S.D.) and the within-day variation of the method was below 6.4% R.S.D. The accuracy of the method was evaluated and showed a relative error less than 5.2%. PFB was found to be stable for 14 days when stored in Tedlar sample bags at room temperature. An even lower detection limit may be obtained by using the more time-consuming process of solid-phase micro extraction; thus, by concentrating PFB on carboxen-PDMS fibres an LLOQ of 0.5 pg PFB/ml was obtained. When five rats were given an i.v. bolus injection of Sonazoid at a dose of 8 microl microbubbles/kg a mean recovery of 96% (range, 81-110%) was found during 24 h; more than 50% was exhaled during the first 30 min after injection.

材料
货号
品牌
产品描述

Supelco
SPME 纤维组件二乙烯基苯/羧基/聚二甲基硅氧烷 (DVB/CAR/PDMS), needle size 24 ga, StableFlex
Supelco
SPME 纤维组件二乙烯基苯/羧基/聚二甲基硅氧烷 (DVB/CAR/PDMS), needle size 24 ga, for use with manual holder
Supelco
SPME 纤维组件二乙烯基苯/羧基/聚二甲基硅氧烷 (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with autosampler
Supelco
SPME 纤维组件二乙烯基苯/羧基/聚二甲基硅氧烷 (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with manual holder or autosampler, fiber L 2 cm
Supelco
SPME 纤维组件二乙烯基苯/羧基/聚二甲基硅氧烷 (DVB/CAR/PDMS), needle size 24 ga, StableFlex, for use with autosampler
Supelco
SPME 纤维组件聚二甲基硅氧烷 (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 24 ga
Supelco
SPME 纤维组件聚二甲基硅氧烷 (PDMS), df 100 μm(PDMS, needle size 24 ga, for use with manual holder
Supelco
ORBO-78 400/200mg,每包 25 支, W,W,W separators, O.D. × L 6 mm × 110 mm, pkg of 25 ea
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with manual holder
Supelco
ORBO Carboxen-564 管, W,F,F separators, O.D. × L 6 mm × 75 mm, pkg of 25 ea, for analyte group MEK (methylethyl ketone)
Supelco
Carboxen®1010 多孔层壁涂开管柱, L × I.D. 30 m × 0.53 mm, average thickness 30 μm
Supelco
手动气泡流量计(标准版), flow meter volume 10 mL, pkg of 1 ea
Supelco
手动气泡流量计(标准版), flow meter volume 25 mL, pkg of 1 ea
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 23 ga, PDMS/DVB StableFlex, for use with autosampler
Supelco
SPME固相微萃取萃取头 Carboxen/聚二甲基硅氧烷 (CAR/PDMS), df 75 μm(CAR/PDMS, for use with manual holder, needle size 24 ga
Supelco
SPME 纤维组件聚二甲基硅氧烷 (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 23 ga
Supelco
Carbopack®吸附剂, matrix Carboxen® 1000, 60-80 mesh, bottle of 10 g
Supelco
手动气泡流量计(标准版), flow meter volume 100 mL, pkg of 1 ea
Supelco
聚丙烯酸酯 (PA) 固相微萃取萃取头, df 85 μm(PA, for use with autosampler, needle size 24 ga
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), df 65 μm(PDMS/DVB, for use with autosampler, needle size 23 ga
Supelco
SPME固相微萃取萃取头 Carboxen/聚二甲基硅氧烷 (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, for use with manual holder, StableFlex fiber
Supelco
SPME固相微萃取萃取头 Carboxen/聚二甲基硅氧烷 (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 24 ga, for use with autosampler
Supelco
SPME固相微萃取萃取头 Carboxen/聚二甲基硅氧烷 (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 23 ga, StableFlex, for use with autosampler
Supelco
聚丙烯酸酯 (PA) 固相微萃取萃取头, df 85 μm(PA, for use with autosampler, needle size 23 ga
Supelco
SPME固相微萃取萃取头 Carboxen/聚二甲基硅氧烷 (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with autosampler
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with manual holder
Supelco
Carboxen® 1006 多孔层壁涂开管柱, L × I.D. 30 m × 0.53 mm, average thickness 30 μm
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with autosampler
Supelco
SPME固相微萃取萃取头 Carboxen/聚二甲基硅氧烷 (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, StableFlex, for use with autosampler
Supelco
Carboxen®1010 多孔层壁涂开管柱, L × I.D. 30 m × 0.32 mm, average thickness 15 μm