跳转至内容
Merck
CN
  • Cross-reactivity of designer drugs, including cathinone derivatives, in commercial enzyme-linked immunosorbent assays.

Cross-reactivity of designer drugs, including cathinone derivatives, in commercial enzyme-linked immunosorbent assays.

Drug testing and analysis (2013-05-17)
Madeleine J Swortwood, W Lee Hearn, Anthony P DeCaprio
摘要

Since the introduction of synthetic heroin, designer drugs have been increasing in prevalence in the United States drug market over the past few decades. Recently, 'legal highs' sold as 'bath salts' have become a household term for one such class of designer drugs. While a number of federal and state bans have been enacted, the abuse of these designer drugs still continues. Few assays have been developed for the comprehensive detection of such compounds, so it is important to investigate how they may or may not react in presumptive screens, i.e. pre-existing commercial immunoassays. In this experiment, 16 different ELISA reagents were evaluated to determine the cross-reactivity of 30 designer drugs, including 24 phenylethylamines (including 8 cathinone derivatives), 3 piperazines, and 3 tryptamines. Cross-reactivity towards most drugs was <4% in assays targeting amphetamine or methamphetamine. Compounds such as MDA, MDMA, ethylamphetamine, and α-methyltryptamine demonstrated cross-reactivities in the range of 30-250%, but data were consistent with both manufacturer's inserts and published literature. When tested against the Randox Mephedrone/Methcathinone kit, cathinone derivatives demonstrated cross-reactivity at concentrations as low as 150 ng/ml. Since this same reagent did not cross-react with other amphetamine-like compounds, it opens the possibility to screen post-mortem specimens without the interference of putrefactive amines. All other assays demonstrated essentially no cross-reactivity towards any of the analytes evaluated. Given these results, a great need exists for more broad-range screening techniques to be applied when analyzing biological specimens by immunoassays for drugs of abuse, specifically the more recent designer drugs.

材料
产品编号
品牌
产品描述

Sigma-Aldrich
甲醇, suitable for HPLC, ≥99.9%
Sigma-Aldrich
甲醇, ACS reagent, ≥99.8%
Sigma-Aldrich
甲醇, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
甲醇, HPLC Plus, ≥99.9%
Sigma-Aldrich
甲醇, anhydrous, 99.8%
Sigma-Aldrich
甲醇, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
甲醇, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
甲醇, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
甲醇, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
甲醇, ACS reagent, ≥99.8%
USP
木精, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
甲醇, BioReagent, ≥99.93%
Supelco
甲醇, analytical standard
Supelco
甲醇, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
甲醇, ACS reagent, ≥99.8%
Sigma-Aldrich
甲醇, puriss., meets analytical specification of Ph Eur, ≥99.7% (GC)
Sigma-Aldrich
甲醇 溶液, contains 0.50 % (v/v) triethylamine
Sigma-Aldrich
甲醇, purification grade, 99.8%