  • On the applicability of comprehensive two-dimensional gas chromatography combined with a fast-scanning quadrupole mass spectrometer for untargeted large-scale metabolomics.

On the applicability of comprehensive two-dimensional gas chromatography combined with a fast-scanning quadrupole mass spectrometer for untargeted large-scale metabolomics.

Journal of chromatography. A (2015-05-16)
Christoph H Weinert, Björn Egert, Sabine E Kulling
摘要

Comprehensive two-dimensional gas chromatography mass spectrometry (GC×GC-MS) offers excellent chromatographic separation performance and superior sensitivity. As such, it is eminently suitable for the analysis of complex biological samples. The applicability of a GC×GC instrument equipped with a fast-scanning qMS detector for large-scale untargeted metabolome analyses was investigated. We optimized the dimensions of an apolar×medium-polar column combination in order to meet detector requirements and to compromise between separation performance and analysis time. The final method enabled a sufficient separation (R≥1.2 or higher) of approx. 90% of all analytes detected in urine within less than 1h. Using the qMS at maximum scan speed (20,000u/s) and choosing a scan range of m/z 60-550, a data acquisition frequency of 33Hz and usually at least 10-13 data points per (2)D peak above the baseline were achieved. Peak area as well as peak height could thus be determined precisely (mean RSD 2.5%). Spectral skewing was limited regarding the data points covering the upper peak half. As a consequence, peak apex spectra could be used for the alignment of analytes in different samples. The linear dynamic range was 1-2.5 orders of magnitude, depending on the analyte. In addition, the slow transition into saturation beyond the linear dynamic range made it possible to exploit an extended "working range" for relative quantification. Long-term stability of the system was demonstrated by the analysis of more than 300 human urine study samples for which detailed repeatability and intermediate precision data are provided. In summary, the GC×GC-qMS system proved to be applicable for untargeted large scale metabolome analyses.

材料
产品编号
品牌
产品描述

Sigma-Aldrich
纯乙醇, 200 proof, anhydrous, ≥99.5%
Sigma-Aldrich
甲醇, anhydrous, 99.8%
Sigma-Aldrich
吡啶, anhydrous, 99.8%
Sigma-Aldrich
纯乙醇, 190 proof, ACS spectrophotometric grade, 95.0%
Sigma-Aldrich
三甲基氯硅烷, ≥98.0% (GC)
Sigma-Aldrich
乙酸酐, ReagentPlus®, ≥99%
Supelco
N-甲基-N-(三甲基硅烷基)三氟乙酰胺, synthesis grade
Sigma-Aldrich
三甲基氯硅烷, purified by redistillation, ≥99%
Sigma-Aldrich
乙酸酐, ACS reagent, ≥98.0%
Sigma-Aldrich
庚烷, anhydrous, 99%
Sigma-Aldrich
纯乙醇, 190 proof, meets USP testing specifications
Supelco
N-甲基-N-(三甲基硅烷基)三氟乙酰胺, BioReagent, for silylations, LiChropur
Sigma-Aldrich
吡啶, ≥99%
Supelco
N -甲基-双(三氟乙酰胺), derivatization grade (GC derivatization), LiChropur, ≥97.0% (GC)
Supelco
10% (v/v) 乙醇标准品, 10 % (v/v) in H2O, analytical standard
Sigma-Aldrich
三甲基氯硅烷, Wacker Chemie AG, ≥99.0% (GC)
Sigma-Aldrich
80% v/v 乙醇固定液, suitable for fixing solution (blood films)
Sigma-Aldrich
三甲基氯硅烷 溶液, 1.0 M in THF
Sigma-Aldrich
纯乙醇, 190 proof, ACS reagent, meets USP testing specifications, Excise Tax-free, Permit for use required
Sigma-Aldrich
纯乙醇, 200 proof, ACS reagent, meets USP testing specifications, Excise Tax-free, Permit for use required
Sigma-Aldrich
纯乙醇, 160 proof, Excise Tax-free, Permit for use required
Sigma-Aldrich
甲醇 溶液, contains 0.50 % (v/v) triethylamine
Sigma-Aldrich
甲醇, purification grade, 99.8%