跳转至内容
Merck
CN
  • Screening for petrochemical contamination in seafood by headspace solid-phase microextraction gas chromatography-mass spectrometry.

Screening for petrochemical contamination in seafood by headspace solid-phase microextraction gas chromatography-mass spectrometry.

Analytical and bioanalytical chemistry (2015-03-23)
F Aladar Bencsath, Ronald A Benner, Ann Abraham, Yuesong Wang, Kathleen R El Said, Edward L E Jester, Steven M Plakas
摘要

A headspace solid-phase microextraction gas chromatography-mass spectrometry (SPME GC-MS) method is described, to screen seafood for volatile organic compounds (VOCs) associated with petrochemical taint. VOCs are extracted from the headspace of heated sample homogenates by adsorption onto a SPME fiber and desorbed for analysis by GC-MS. Targeted compounds are determined semi-quantitatively using representative calibration standards for the various classes (alkanes, alkylbenzenes, indanes/tetralins, and naphthalenes) of VOCs analyzed. Sample preparation is minimal, and the analyses are rapid and automated with a capacity of 50 samples per day. The method was optimized in terms of headspace temperature, sample heating time, extraction time, and desorption time using oyster samples fortified with target compounds. Calibrations for hydrocarbon components were linear in the range of 8.3-167 ng/g; the limit of detection ranged between 0.05 and 0.21 ng/g, and the limit of quantitation between 0.16 and 0.69 ng/g. Good precision (RSD < 10 % at 16.7 ng/g for individual VOCs) and accuracy (recovery range 89-118 % at 25 ng/g) were obtained in oyster, crab, shrimp, and finfish matrices. The trueness of the method was demonstrated by quantifying VOCs at 1-2-ppb levels in oyster fortified with certified reference material NIST SRM 1491a. Following single laboratory validation, the method was employed for the determination of VOCs in seafood exposed to oil contaminated seawater and for the determination of background VOC levels in seafood species from the Gulf of Mexico and local food stores. The method as described can be used to supplement human sensory testing for petrochemical taint in seafood.

材料
Product Number
品牌
产品描述

Sigma-Aldrich
Triton X-100, laboratory grade
Sigma-Aldrich
十四烷, ≥99%
Sigma-Aldrich
萘, 99%
Sigma-Aldrich
对二甲苯, anhydrous, ≥99%
Sigma-Aldrich
均三甲苯, 98%
Supelco
SPME 纤维组件聚二甲基硅氧烷 (PDMS), 100 μm PDMS, Fused Silica (1 cm), needle size 23 ga, Autosampler, pk of 3, red hub
Sigma-Aldrich
十四烷, olefin free, ≥99.0% (GC)
Supelco
SPME 纤维组件聚二甲基硅氧烷 (PDMS), 100 μm PDMS, Fused Silica (1 cm), needle size 24 ga, Manual Holder, pk of 3, red hub
Sigma-Aldrich
1-甲基萘, 95%
Sigma-Aldrich
萘-d8, 99 atom % D, ≥98% (CP)
Sigma-Aldrich
十三烷, ≥99%
Supelco
SPME 纤维组件聚二甲基硅氧烷 (PDMS), 100 μm PDMS, Fused Silica (1 cm), needle size 24 ga, Autosampler, pk of 3, red hub
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), 65 μm PDMS/DVB, Fused Silica (1 cm), needle size 24 ga, Manual Holder, pk of 3, blue hub
Sigma-Aldrich
萘, suitable for scintillation, ≥99%
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), 65 μm PDMS/DVB, StableFlex (1 cm), needle size 23 ga, Autosampler, pk of 3, pink hub
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), 65 μm PDMS/DVB, Fused Silica (1 cm), needle size 24 ga, Autosampler, pk of 3, blue hub
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), 65 μm PDMS/DVB, StableFlex (1 cm), needle size 24 ga, Manual Holder, pk of 3, pink hub
Sigma-Aldrich
1,2,3,4-四氢萘, anhydrous, 99%
Supelco
聚丙烯酸酯 (PA) 固相微萃取萃取头, 85 μm Polyacrylate, Fused Silica (1 cm), needle size 24 ga, Autosampler, pk of 3, white hub
Supelco
固相微萃取便携式现场采样器, coating PDMS/DVB
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), 65 μm PDMS/DVB, StableFlex (1 cm), needle size 24 ga, Autosampler, pk of 3, pink hub
Sigma-Aldrich
2,6-二甲基萘, 99%
Supelco
聚丙烯酸酯 (PA) 固相微萃取萃取头, 85 μm Polyacrylate, Fused Silica (1 cm), needle size 23 ga, Autosampler, pk of 3, white hub
Sigma-Aldrich
1-甲基萘, ≥95%
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), 65 μm PDMS/DVB, Fused Silica (1 cm), needle size 23 ga, Manual Holder, pk of 3, blue hub
Supelco
固相微萃取便携式现场采样器, coating PDMS
Sigma-Aldrich
均三甲苯, reagent grade, 97%
Supelco
固相微萃取 StableFlex 萃取头组合套件, Assortment, StableFlex (1 cm), needle size 24 ga, Manual Holder, pk of 4
Supelco
SPME 纤维组件聚二甲基硅氧烷 (PDMS), 100 μm PDMS, Fused Silica (1 cm), needle size 23 ga, Manual Holder, pk of 3, red hub
Supelco
固相微萃取 StableFlex 萃取头组合套件, Assortment, StableFlex (1 cm), needle size 23 ga, Autosampler, pk of 4