跳转至内容
Merck
CN
  • Development, validation, and application of an ultra-performance liquid chromatography-sector field inductively coupled plasma mass spectrometry method for simultaneous determination of six organotin compounds in human serum.

Development, validation, and application of an ultra-performance liquid chromatography-sector field inductively coupled plasma mass spectrometry method for simultaneous determination of six organotin compounds in human serum.

Talanta (2015-06-07)
Keith E Levine, Daniel J Young, Scott E Afton, James M Harrington, Amal S Essader, Frank X Weber, Reshan A Fernando, Kristina Thayer, Elizabeth E Hatch, Veronica G Robinson, Suramya Waidyanatha
摘要

Organotin compounds (OTCs) are heavily employed by industry for a wide variety of applications, including the production of plastics and as biocides. Reports of environmental prevalence, differential toxicity between OTCs, and poorly characterized human exposure have fueled the demand for sensitive, selective speciation methods. The objective of this investigation was to develop and validate a rapid, sensitive, and selective analytical method for the simultaneous determination of a suite of organotin compounds, including butyl (mono-, di-, and tri-substituted) and phenyl (mono-, di-, and tri-substituted) species in human serum. The analytical method utilized ultra-performance liquid chromatography (UPLC) coupled with sector field inductively coupled plasma mass spectrometry (SF-ICP-MS). The small (sub-2 µm) particle size of the UPLC column stationary phase and the sensitivity of the SF-ICP-MS enabled separation and sensitive determination of the analyte suite with a runtime of approximately 3 min. Validation activities included demonstration of method linearity over the concentration range of approximately 0.250-13.661 ng mL(-1), depending on the species; intraday precision of less than 21%, interday precision of less than 18%, intraday accuracy of -5.3% to 19%, and interday accuracy of -14% to 15% for all species; specificity, and matrix impact. In addition, sensitivity, and analyte stability under different storage scenarios were evaluated. Analyte stability was found to be limited for most species in freezer, refrigerator, and freeze-thaw conditions. The validated method was then applied for the determination of the OTCs in human serum samples from women participating in the Snart-Foraeldre/MiljØ (Soon-Parents/Environment) Study. The concentration of each OTC ranged from below the experimental limit of quantitation to 10.929 ng tin (Sn) mL(-1) serum. Speciation values were confirmed by a total Sn analysis.

材料
产品编号
品牌
产品描述

Sigma-Aldrich
二氯甲烷, anhydrous, ≥99.8%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
三乙基胺, ≥99.5%
Sigma-Aldrich
甲醇, anhydrous, 99.8%
Sigma-Aldrich
三乙基胺, ≥99%
Sigma-Aldrich
三乙基胺, BioUltra, ≥99.5% (GC)
Sigma-Aldrich
三乙基胺, puriss. p.a., ≥99.5% (GC)
Sigma-Aldrich
2-巯基苯并, 97%
Sigma-Aldrich
乙酸, suitable for luminescence, BioUltra, ≥99.5% (GC)
Sigma-Aldrich
三乙基胺, for amino acid analysis, ≥99.5% (GC)
Sigma-Aldrich
乙酸, ≥99.5%, FCC, FG
Sigma-Aldrich
乙酸, natural, ≥99.5%, FG
Sigma-Aldrich
二苯并噻吩, 98%
Sigma-Aldrich
二氯甲烷, suitable for HPLC, ≥99.9%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
二苯并噻吩, ≥99%
Sigma-Aldrich
三乙基胺, ampule, ≥99.5% (GC)
Sigma-Aldrich
甲醇, suitable for NMR (reference standard)
Sigma-Aldrich
乙酸-12C2, 99.9 atom % 12C
Sigma-Aldrich
甲醇 溶液, contains 0.50 % (v/v) triethylamine
Sigma-Aldrich
甲醇, purification grade, 99.8%