跳转至内容
Merck
CN
  • Rapid label-free determination of ketamine in whole blood using secondary ion mass spectrometry.

Rapid label-free determination of ketamine in whole blood using secondary ion mass spectrometry.

Talanta (2015-06-17)
Hua-Yang Liao, Jung-Hsuan Chen, Jing-Jong Shyue, Chia-Tung Shun, Huei-Wen Chen, Su-Wei Liao, Chih-Kang Hong, Pai-Shan Chen
摘要

A fast and accurate drug screening to identify the possible presence of a wide variety of pharmaceutical and illicit drugs is increasingly requested in forensic and clinical toxicology. The current first-line screening relies on immunoassays. They determine only certain common drugs of which antibodies are commercially available. To address the issue, a rapid screening using secondary ion mass spectrometry (SIMS) has been developed. In the study, SIMS directly analyzed ketamine in whole blood without any pretreatment. While the untreated blood has a complicated composition, principal-components analysis (PCA) is used to detect unknown specimens by building up an analytical model from blank samples which were spiked with ketamine at 100 ng mL(-1), to simulate the presence of ketamine. Each characteristics m/z is normalized and scaled by multiplying the root square of intensity and square of corresponding m/z, developed by National Institute of Standards and Technology (NIST). Using linear regression and the result of PCA, this study enables to correctly distinguish ketamine positive and negative groups in an unknown set of specimens. The quantity of ketamine in an unknown set was determined using gas chromatography-mass spectrometry (GC-MS) as the reference methodology. Instead limited by commercially available antibodies, SIMS detects target molecules straight despite the label-free detection capabilities of SIMS, additional data processing (here, PCA) can be used to fully analyse the produced data, which extends the range of analytes of interest on drug screening. Furthermore, extremely low sample volume, 5 µL, is required owing to the high spatial resolution of SIMS. In addition, while the whole blood is analyzed within 3 min, the whole analysis has been shortened significantly and high throughput can be achieved.

材料
产品编号
品牌
产品描述

Sigma-Aldrich
二氯甲烷, anhydrous, ≥99.8%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
甲醇, anhydrous, 99.8%
Sigma-Aldrich
正己烷, anhydrous, 95%
Sigma-Aldrich
无水碳酸钠, anhydrous, powder, 99.999% trace metals basis
Sigma-Aldrich
无水碳酸钠, BioXtra, ≥99.0%
Sigma-Aldrich
二氯甲烷, suitable for HPLC, ≥99.9%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
无水碳酸钠, BioUltra, anhydrous, ≥99.5% (calc. on dry substance, T)
Sigma-Aldrich
甲醇, suitable for NMR (reference standard)
Sigma-Aldrich
甲醇 溶液, suitable for NMR (reference standard), 4% in methanol-d4 (99.8 atom % D), NMR tube size 3 mm × 8 in.
Sigma-Aldrich
碳酸钠-12C, 99.9 atom % 12C
Sigma-Aldrich
甲醇 溶液, contains 0.50 % (v/v) triethylamine
Sigma-Aldrich
无水碳酸钠, Vetec, reagent grade, ≥99.5%
Sigma-Aldrich
甲醇, purification grade, 99.8%