跳转至内容
Merck
CN
  • Quantitative passive soil vapor sampling for VOCs--Part 4: Flow-through cell.

Quantitative passive soil vapor sampling for VOCs--Part 4: Flow-through cell.

Environmental science. Processes & impacts (2014-04-02)
Todd McAlary, Hester Groenevelt, Suresh Seethapathy, Paolo Sacco, Derrick Crump, Michael Tuday, Brian Schumacher, Heidi Hayes, Paul Johnson, Louise Parker, Tadeusz Górecki
摘要

This paper presents a controlled experiment comparing several quantitative passive samplers for monitoring concentrations of volatile organic compound (VOC) vapors in soil gas using a flow-through cell. This application is simpler than conventional active sampling using adsorptive tubes because the flow rate does not need to be precisely measured and controlled, which is advantageous because the permeability of subsurface materials affects the flow rate and the permeability of geologic materials is highly variable. Using passive samplers in a flow-through cell, the flow rate may not need to be known exactly, as long as it is sufficient to purge the cell in a reasonable time and minimize any negative bias attributable to the starvation effect. An experiment was performed in a 500 mL flow-through cell using a two-factor, one-half fraction fractional factorial test design with flow rates of 80, 670 and 930 mL min(-1) and sample durations of 10, 15 and 20 minutes for each of five different passive samplers (passive Automatic Thermal Desorption Tube, Radiello®, SKC Ultra, Waterloo Membrane Sampler™ and 3M™ OVM 3500). A Summa canister was collected coincident with each passive sampler and analyzed by EPA Method TO-15 to provide a baseline for comparison of the passive sampler concentrations. The passive sampler concentrations were within a factor of 2 of the Summa canister concentrations in 32 of 35 cases. Passive samples collected at the low flow rate and short duration showed low concentrations, which is likely attributable to insufficient purging of the cell after sampler placement.

材料
产品编号
品牌
产品描述

radiello 小柱吸附剂, for sampling BTEX and VOCs (CS2 Desorption), matrix SS net (100 mesh, 5.8 mm diam.), activated with activated charcoal (30-50 mesh), pk of 20
radiello 小柱吸附剂, for sampling Aldehydes, matrix SS net with 2,4-DNPH coated FLORISIL®, pk of 20
radiello 扩散体外壳, white, configured for general use, pk of 20
radiello 三角支撑板, pk of 20
radiello 小柱吸附剂, for sampling Ammonia (NH3), matrix microporous PE impregnated with phosphoric acid, pk of 20
radiello 扩散体外壳, yellow, configured for reduced sampling rates, pk of 20
radiello 扩散体外壳, blue, configured for sampling light sensitive compounds, pk of 20
radiello 小柱吸附剂, for sampling BTEX and VOCs (thermal desorption), matrix SS net (3 x 8 μm, 4.8 mm diam.), Carbograph, pk of 20
Supelco
radiello 亚甲蓝校正标准样,用于 H2S(硫化氢), pkg of 100 mL
radiello 室外防护罩, pk of 10
radiello BTEX/VOC Starter试剂盒,CS2解吸
radiello BTEX/VOC 起动包,热解吸
radiello 竖直连接头, threaded for standard use, pk of 20
radiello 扩散体外壳, permeative, configured for anaesthetic gases and vapors, pk of 20
radiello 过滤套装, pk of 20
radiello 条形码标签, pk of 198
radiello 麻醉气体和蒸气采样器
radiello Starter试剂盒
Supelco
radiello BTEX 校正套装(热解吸)
radiello 空储存管, polypropylene (with stopper), volume 12 mL, pk of 100
Supelco
radiello醛校准标准品, 50 μg/mL each component in acetonitrile, pkg of 10 mL
Radiello 现场温度计, Includes one standard Radiello vertical adapter (RAD122) for each thermometer, configured for standard use, pk of 3
radiello 空储存管, glass (with stopper), volume 2.8 mL, pk of 100
Supelco
radiello BTEX 校正套装(CS2 解吸)
radiello 小柱吸附剂, for sampling Anaesthetic Gases/Vapors, matrix SS net with mix of mol sieve and activated charcoal (30-50 mesh), pk of 20
radiello 1,3-丁二烯起动包,热解吸, pkg of 1 kit (2 RAD141 adsorbing cartridges and barcode labels, 1 RAD1202 yellow diffusive body, 1 RAD121 triangular support plate, 1 instruction sheet)
radiello 固定条备件, for use with Radiello Outdoor Shelter, pk of 100
radiello 夹, suspending Radiello triangular support plate, pk of 20
Radiello 现场温度计, Reader, pk of 1