跳转至内容
Merck
CN
  • Formation of volatile halogenated by-products during chlorination of isoproturon aqueous solutions.

Formation of volatile halogenated by-products during chlorination of isoproturon aqueous solutions.

Chemosphere (2001-10-11)
A Lopez, G Mascolo, R Ciannarella, G Tiravanti
摘要

The present paper deals with the formation of volatile halogenated by-products (POX) during the chlorination (160 mg/l) of aqueous solutions of the herbicide isoproturon (40 mg/l). Chlorination reactions have been carried out over 48 h, at ambient temperature, at two pHs (6 and 9) and in the presence or not of bromide ions (80 mg/l). The main results obtained have been as follows: (1) in the presence of bromide, isoproturon degradation is rather fast and it results affected by pH, complete isoproturon degradation is achieved within 1 and 15 min at pH 6 and 9, respectively; (2) in the absence of bromide herbicide degradation is slow (complete degradation is achieved within 180 min) and it is not affected by pH; (3) at pH 6, regardless of the presence of bromide, the maximum amount of POX formed is low (approximately 15 micromol X-/l) and remains constant during the reaction; (4) at pH 9 the amount of POX formed is far greater and continuously increases during the reaction, reaching a value of about 110 micromol X-/l after 48 h; (5) two different groups of by-products have been identified by solid phase micro extraction (SPME)-gas chromatography (GC)-mass spectrometry (MS) for the reactions carried out with or without bromide; among them, aliphatic as well as aromatic by-products containing chlorine, bromine or both halogens are present even though the most abundant are halogenated-methane derivatives (haloforms); pH value affects the amount of these by-products but does not modify their chemical nature.

材料
产品编号
品牌
产品描述

Supelco
SPME萃取头组件, 50/30µm DVB/CAR/PDMS, StableFlex (1 cm), needle size 23 ga, Autosampler, pk of 3, plain gray hub
Supelco
SPME萃取头组件, 50/30µm DVB/CAR/PDMS, StableFlex (2cm), needle size 24 ga, Autosampler, pk of 3, notched gray hub
Supelco
SPME萃取头组件, 50/30µm DVB/CAR/PDMS, StableFlex (1cm), needle size 24 ga, Manual Holder, pk of 3, plain gray hub
Supelco
SPME萃取头组件, 50/30µm DVB/CAR/PDMS, StableFlex (2cm), needle size 23 ga, Autosampler, pk of 3, notched gray hub
Supelco
SPME 纤维组件聚二甲基硅氧烷 (PDMS), 100 μm PDMS, Fused Silica (1 cm), needle size 23 ga, Autosampler, pk of 3, red hub
Supelco
SPME萃取头组件, 50/30µm DVB/CAR/PDMS, StableFlex (1 cm), needle size 24 ga, Autosampler, pk of 3, plain gray hub
Supelco
SPME 纤维组件聚二甲基硅氧烷 (PDMS), 100 μm PDMS, Fused Silica (1 cm), needle size 24 ga, Manual Holder, pk of 3, red hub
Supelco
SPME固相微萃取萃取头 Carboxen/聚二甲基硅氧烷 (CAR/PDMS), 75 μm CAR/PDMS, Fused Silica (1 cm), needle size 24 ga, Manual Holder, pk of 3, black hub
Supelco
SPME 纤维组件聚二甲基硅氧烷 (PDMS), 100 μm PDMS, Fused Silica (1 cm), needle size 24 ga, Autosampler, pk of 3, red hub
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), 65 μm PDMS/DVB, Fused Silica (1 cm), needle size 24 ga, Manual Holder, pk of 3, blue hub
Supelco
SPME固相微萃取萃取头 Carboxen/聚二甲基硅氧烷 (CAR/PDMS), 75 μm CAR/PDMS, Fused Silica (1 cm), needle size 24 ga, Autosampler, pk of 3, black hub
Supelco
SPME固相微萃取萃取头 Carboxen/聚二甲基硅氧烷 (CAR/PDMS), 85 μm CAR/PDMS, StableFlex (1 cm), needle size 23 ga, Autosampler, pk of 3, light blue hub
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), 65 μm PDMS/DVB, StableFlex (1 cm), needle size 23 ga, Autosampler, pk of 3, pink hub
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), 65 μm PDMS/DVB, Fused Silica (1 cm), needle size 24 ga, Autosampler, pk of 3, blue hub
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), 65 μm PDMS/DVB, StableFlex (1 cm), needle size 24 ga, Manual Holder, pk of 3, pink hub
Supelco
SPME固相微萃取萃取头 Carboxen/聚二甲基硅氧烷 (CAR/PDMS), 85 μm CAR/PDMS, StableFlex (1 cm), needle size 24 ga, Manual Holder, pk of 3, light blue hub
Supelco
聚丙烯酸酯 (PA) 固相微萃取萃取头, 85 μm Polyacrylate, Fused Silica (1 cm), needle size 24 ga, Autosampler, pk of 3, white hub
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), 65 μm PDMS/DVB, StableFlex (1 cm), needle size 24 ga, Autosampler, pk of 3, pink hub
Supelco
固相微萃取便携式现场采样器, coating PDMS/DVB
Supelco
SPME固相微萃取萃取头 Carboxen/聚二甲基硅氧烷 (CAR/PDMS), 85 μm CAR/PDMS, StableFlex (1 cm), needle size 24 ga, Autosampler, pk of 3, light blue hub
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), 65 μm PDMS/DVB, Fused Silica (1 cm), needle size 23 ga, Manual Holder, pk of 3, blue hub
Supelco
聚丙烯酸酯 (PA) 固相微萃取萃取头, 85 μm Polyacrylate, Fused Silica (1 cm), needle size 23 ga, Autosampler, pk of 3, white hub
Supelco
固相微萃取便携式现场采样器, coating PDMS
Supelco
固相微萃取 StableFlex 萃取头组合套件, Assortment, StableFlex (1 cm), needle size 24 ga, Manual Holder, pk of 4
Supelco
SPME固相微萃取萃取头 Carboxen/聚二甲基硅氧烷 (CAR/PDMS), 75 μm CAR/PDMS, Fused Silica (1 cm), needle size 23 ga, Autosampler, pk of 3, black hub
Supelco
SPME 纤维组件聚二甲基硅氧烷 (PDMS), 100 μm PDMS, Fused Silica (1 cm), needle size 23 ga, Manual Holder, pk of 3, red hub
Supelco
固相微萃取 StableFlex 萃取头组合套件, Assortment, StableFlex (1 cm), needle size 23 ga, Autosampler, pk of 4
Supelco
固相微萃取便携式现场采样器, coating CAR/PDMS
Supelco
SPME 纤维分类套件 4, Assortment #4, Fused Silica (1 cm), size 24 ga, Manual Holder, pk of 3
Supelco
Carbowax-聚乙二醇 (PEG) 固相微萃取萃取头, 60 μm PEG, Metal Alloy (1 cm), needle size 23 ga, Autosampler, pk of 3, purple hub