跳转至内容
Merck
CN
  • Determination of alachlor, metolachlor, and their acidic metabolites in soils by microwave-assisted extraction (MAE) combined with solid phase extraction (SPE) coupled with GC-MS and HPLC-UV analysis.

Determination of alachlor, metolachlor, and their acidic metabolites in soils by microwave-assisted extraction (MAE) combined with solid phase extraction (SPE) coupled with GC-MS and HPLC-UV analysis.

Journal of separation science (2007-09-01)
Zisis Vryzas, Ageliki Tsaboula, Euphemia Papadopoulou-Mourkidou
摘要

A well-validated analytical method based on microwave-assisted extraction (MAE) and SPE is presented for the combined analysis of alachlor, alachlor-oxanilic acid (OXA), alachlor-ethanesulfonic acid (ESA), metolachlor, metolachlor-OXA, metolachlor-ESA residues in soils. Extraction of solutes by soil sample was carried out by MAE for 20 min at 100 degrees C in the presence of 50 mL solution (methanol/water 50:50), the extract was subsequently passed through C18 cartidges and fractionated into two fractions, the first with parent compounds (PCs) analyzed with GC-MS and the second one containing the metabolites analyzed with HPLC. For the SPE step, various types of sorbents (Environmental C18, tC18, Supelclean ENVI-carb, and LiChrolut EN) have been used, and their respective advantages and disadvantages are discussed. After the method optimization, average recovery values of all solutes were > 71% in the 50-500 microg/kg fortification range with RSD <10%. The LOQ and LOD were 10-50 and 5-10 microg/kg, respectively. The method was validated with two types of soils (1 and 2.4% organic matter) and in fresh (12 h aging), intermediate (1 wk aging), and aged (1 month aging) spiked samples. Moreover, residue levels determined after field application of alachlor or metolachlor were higher when soils were processed using this method than with a comparison method based on an overnight flask shaking (FS) of soil suspension.

材料
产品编号
品牌
产品描述

Supelco
Supel QuE, PSA/C18/ENVI-Carb Tube, pack of 100, AOAC® 2007.01
Supelco
Supel QuE, PSA/ENVI-Carb Tube 2, pk of 50, suitable for EN 15662:2008 per BS, centrifuge tube volume 15 mL , Shaker Compatible
Supelco
Supel QuE, PSA/ENVI-Carb Tube 1, pk of 50, suitable for EN 15662:2008 per BS, centrifuge tube volume 15 mL , Shaker Compatible
Supelco
Supel QuE, PSA/C18/ENVI-Carb Tube, pk of 50, AOAC® 2007.01, centrifuge tube volume 15 mL , Shaker Compatible
Supelco
Supel QuE, PSA/ENVI-Carb (EN) Cleanup Tube 2, pack of 100, suitable for EN 15662:2008 per BS
Supelco
Supel QuE, PSA/ENVI-Carb (EN) Cleanup Tube 1, pack of 100, suitable for EN 15662:2008 per BS