跳转至内容
Merck
CN
  • Field comparison of passive samplers versus UV-photometric analyser to measure surface ozone in a Mediterranean area.

Field comparison of passive samplers versus UV-photometric analyser to measure surface ozone in a Mediterranean area.

Journal of environmental monitoring : JEM (2007-06-08)
J M Delgado Saborit, V J Esteve Cano
摘要

The aim of the present work is to compare the performance of the Radiello passive sampler versus UV-photometric ozone analyser to measure surface ozone in a Mediterranean Spanish coastal area. The comparison presented considers precision, bias, accuracy, selectivity, detection limit, cost and applicability. For assessing precision, co-located samplers were exposed in duplicate in two reference-sampling sites, beside UV-photometric ozone analyser. Bias was calculated comparing results of passive samplers exposed in three reference-sampling sites and two contrast-sampling sites with the measurements given by the reference analysers. Accuracy was calculated following the EN 482:1994 standard. The limit of detection was calculated as 3 times the standard deviation of the blanks in a batch of passive samplers. The compared Radiello passive samplers give a precision of 5.2%, a bias of 13.8%, an accuracy of 20.5% and a limit of detection of 12.6 microg m(-3). The selectivity and applicability of this methodology is in both aspects successful. Surface ozone levels measured with passive samplers were comparable with the averaged values measured with the reference analyser both in the reference-sampling sites and in the contrast-sampling sites.

材料
Product Number
品牌
产品描述

radiello 小柱吸附剂, for sampling BTEX and VOCs (CS2 Desorption), matrix SS net (100 mesh, 5.8 mm diam.), activated with activated charcoal (30-50 mesh), pk of 20
radiello 小柱吸附剂, for sampling Aldehydes, matrix SS net with 2,4-DNPH coated FLORISIL®, pk of 20
radiello 扩散体外壳, white, configured for general use, pk of 20
radiello 三角支撑板, pk of 20
radiello 小柱吸附剂, for sampling Ammonia (NH3), matrix microporous PE impregnated with phosphoric acid, pk of 20
radiello 扩散体外壳, yellow, configured for reduced sampling rates, pk of 20
radiello 扩散体外壳, blue, configured for sampling light sensitive compounds, pk of 20
radiello 小柱吸附剂, for sampling BTEX and VOCs (thermal desorption), matrix SS net (3 x 8 μm, 4.8 mm diam.), Carbograph, pk of 20
Supelco
radiello 亚甲蓝校正标准样,用于 H2S(硫化氢), pkg of 100 mL
radiello 室外防护罩, pk of 10
radiello BTEX/VOC Starter试剂盒,CS2解吸
radiello BTEX/VOC 起动包,热解吸
radiello 竖直连接头, threaded for standard use, pk of 20
radiello 扩散体外壳, permeative, configured for anaesthetic gases and vapors, pk of 20
radiello 过滤套装, pk of 20
radiello 条形码标签, pk of 198
radiello 麻醉气体和蒸气采样器
radiello Starter试剂盒
Supelco
radiello BTEX 校正套装(热解吸)
radiello 空储存管, polypropylene (with stopper), volume 12 mL, pk of 100
Supelco
radiello醛校准标准品, 50 μg/mL each component in acetonitrile, pkg of 10 mL
Radiello 现场温度计, Includes one standard Radiello vertical adapter (RAD122) for each thermometer, configured for standard use, pk of 3
radiello 空储存管, glass (with stopper), volume 2.8 mL, pk of 100
Supelco
radiello BTEX 校正套装(CS2 解吸)
radiello 小柱吸附剂, for sampling Anaesthetic Gases/Vapors, matrix SS net with mix of mol sieve and activated charcoal (30-50 mesh), pk of 20
radiello 1,3-丁二烯起动包,热解吸, pkg of 1 kit (2 RAD141 adsorbing cartridges and barcode labels, 1 RAD1202 yellow diffusive body, 1 RAD121 triangular support plate, 1 instruction sheet)
radiello 固定条备件, for use with Radiello Outdoor Shelter, pk of 100
radiello 夹, suspending Radiello triangular support plate, pk of 20
Radiello 现场温度计, Reader, pk of 1