Skip to Content
Merck
CN
  • Genotoxicity assessment of mouse oocytes by comet assay before vitrification and after warming with three vitrification protocols.

Genotoxicity assessment of mouse oocytes by comet assay before vitrification and after warming with three vitrification protocols.

Fertility and sterility (2013-06-13)
Anais Berthelot-Ricou, Jeanne Perrin, Carole di Giorgio, Michel de Meo, Alain Botta, Blandine Courbiere
ABSTRACT

To assess the genotoxicity of three oocyte vitrification protocols. Murine assay. Biogenotoxicology research laboratory. CD1 female mice. Three mouse oocyte groups were exposed to three commercialized human oocyte vitrification protocols. Protocols 1 and 2 contained dimethyl sulfoxide and ethylene glycol (EG), and protocol 3 contained EG and 1,2-propanediol (PrOH). DNA damage was first evaluated by comet assay after oocyte exposure to the three different equilibration and vitrification solutions. Comet assay was also performed after full vitrification and warming procedure and compared with a negative control group (oocytes stored in medium culture only) and a positive control group (oocytes exposed to hydrogen peroxide just before comet assay). DNA damage was quantified as Olive tail moment (OTM). Statistical analysis consisted of a Shapiro-Wilk test. Then, median protocol OTM was compared with the negative control group with the Mann-Whitney U test. The difference was considered to be statistically significant if the P value was <.05. In both parts of our study, protocols 1 and 2 did not induce significant DNA damage, whereas protocol 3 induced statistically higher DNA damage compared with the negative control group. Vitrification protocols containing PrOH induced significant DNA damage on mouse oocytes, both before cooling and after warming. Therefore, for the moment, we prefer vitrification techniques without PrOH while we await more studies on PrOH toxicity and long-term evaluation.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Ethylene glycol, anhydrous, 99.8%
Sigma-Aldrich
Ethylene glycol, BioUltra, ≥99.5% (GC)
Supelco
Ethylene glycol solution, suitable for NMR (reference standard), 80% in DMSO-d6 (99.9 atom % D), NMR tube size 5 mm × 8 in.
Supelco
Dimethyl Sulfoxide, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Ethylene glycol, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Ethylene glycol, analytical standard
Sigma-Aldrich
Ethylene glycol, Vetec, reagent grade, 98%
Sigma-Aldrich
Ethylene glycol, ReagentPlus®, ≥99%
Sigma-Aldrich
Ethylene glycol, spectrophotometric grade, ≥99%
Sigma-Aldrich
Ethylene glycol 5 M solution
Sigma-Aldrich
Dimethyl sulfoxide, anhydrous, ≥99.9%
Sigma-Aldrich
Dimethyl sulfoxide, sterile-filtered, BioPerformance Certified, meets EP, USP testing specifications, suitable for hybridoma
Supelco
Dimethyl sulfoxide, analytical standard
Sigma-Aldrich
Dimethyl sulfoxide, Molecular Biology
Sigma-Aldrich
Dimethyl sulfoxide, Hybri-Max, sterile-filtered, BioReagent, suitable for hybridoma, ≥99.7%
Sigma-Aldrich
Dimethyl sulfoxide, meets EP testing specifications, meets USP testing specifications
Sigma-Aldrich
Dimethyl sulfoxide, PCR Reagent
Sigma-Aldrich
Dimethyl sulfoxide, ≥99.5% (GC), suitable for plant cell culture
Sigma-Aldrich
Dimethyl sulfoxide, BioUltra, Molecular Biology, ≥99.5% (GC)
Supelco
Dimethyl sulfoxide, for inorganic trace analysis, ≥99.99995% (metals basis)
Sigma-Aldrich
Dimethyl sulfoxide, Vetec, reagent grade, 99%
Sigma-Aldrich
Dimethyl sulfoxide, ReagentPlus®, ≥99.5%
Sigma-Aldrich
Dimethyl sulfoxide, ACS reagent, ≥99.9%
Sigma-Aldrich
Dimethyl sulfoxide, puriss. p.a., dried, ≤0.02% water
Sigma-Aldrich
Dimethyl sulfoxide, puriss. p.a., ACS reagent, ≥99.9% (GC)
Sigma-Aldrich
Dimethyl sulfoxide, suitable for HPLC, ≥99.7%