Skip to Content
Merck
CN
  • Use of a carboxylesterase inhibitor of phenylmethanesulfonyl fluoride to stabilize epothilone D in rat plasma for a validated UHPLC-MS/MS assay.

Use of a carboxylesterase inhibitor of phenylmethanesulfonyl fluoride to stabilize epothilone D in rat plasma for a validated UHPLC-MS/MS assay.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2014-08-26)
Long Yuan, Yunlin Fu, Duxi Zhang, Yuan-Qing Xia, Qianping Peng, Anne-Françoise Aubry, Mark E Arnold
ABSTRACT

A sensitive, accurate and rugged UHPLC-MS/MS method was developed and validated for the quantitation of Epothilone D (EpoD), a microtubule stabilizer in development for treatment of Alzeimer's disease, in rat plasma. The ester group in EpoD can be hydrolyzed by esterases in blood or plasma, which creates a stability concern for the bioanalysis of EpoD. Species differences in the stability of EpoD in plasma were observed. Carboxylesterases were identified as the likely esterases responsible for the hydrolysis of EpoD in plasma ex vivo, and the cause of the species different stability. Phenylmethanesulfonyl fluoride, a carboxylesterase inhibitor, was used to stabilize EpoD in rat blood during sample collection, processing, and storage. A systematic method screening and optimization strategy was used to improve the assay sensitivity and minimize potential bioanalytical risks. The stabilized plasma samples were extracted by liquid-liquid extraction. Chromatographic separation was achieved on an Acquity UPLC BEH Phenyl column with a gradient elution. EpoD and its stable isotope labeled internal standards were detected by positive ion electrospray tandem mass spectrometry. The standard curve, which ranged from 0.100 to 100ng/mL was fitted to a 1/x(2) weighted linear regression model. The intra-assay precision was within ±3.6% CV and inter-assay precision was within ±4.2% CV. The assay accuracy was within ±8.3% of the nominal values. Assay recovery of EpoD was high (∼90%) and matrix effect was minimal (1.02-1.05). EpoD was stable in stabilized rat plasma for at least 30h at room temperature, 180 days at -20°C, and following three freeze-thaw cycles. The validated method was successfully applied to sample analysis in toxicology studies.

MATERIALS
Product Number
Brand
Product Description

Supelco
Ethanol solution, certified reference material, 2000 μg/mL in methanol
Supelco
Dehydrated Alcohol, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Ammonium formate, ≥99.995% trace metals basis
Supelco
Ammonium formate, eluent additive for LC-MS, LiChropur, ≥99.0%
Sigma-Aldrich
Ammonium formate, BioUltra, ≥99.0% (calc. based on dry substance, NT)
Sigma-Aldrich
1-Chlorobutane, biotech. grade, ≥99.8%
Sigma-Aldrich
Ethanol Fixative 80% v/v, suitable for fixing solution (blood films)
Supelco
Ethanol standards 10% (v/v), 10 % (v/v) in H2O, analytical standard
Sigma-Aldrich
Phenylmethanesulfonyl fluoride, ≥98.5% (GC)
Sigma-Aldrich
Phenylmethanesulfonyl fluoride, ≥99.0% (T)
Sigma-Aldrich
1-Chlorobutane, anhydrous, 99.5%
Sigma-Aldrich
1-Chlorobutane, suitable for HPLC, ≥99.8%
USP
Dehydrated Alcohol, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Ammonium formate, reagent grade, 97%
Sigma-Aldrich
1-Chlorobutane, ReagentPlus®, 99%
Supelco
Residual Solvent - Acetonitrile(solution in DMSO), Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Ethyl alcohol, Pure 190 proof, for molecular biology
Supelco
Acetonitrile(Neat), Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Ethyl alcohol, Pure, 190 proof, ACS spectrophotometric grade, 95.0%
Sigma-Aldrich
Ethyl alcohol, Pure, 190 proof, meets USP testing specifications
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Sigma-Aldrich
Ammonium formate solution, BioUltra, 10 M in H2O
Supelco
Ammonium formate solution, 10 mM in H2O, suitable for HPLC
Sigma-Aldrich
Acetonitrile, Preparateur, ≥99.9% (GC), One-time steel-plastic (SP) drum
Sigma-Aldrich
Ethanol, tested according to Ph. Eur.
Supelco
Ethanol, standard for GC
Sigma-Aldrich
Ethyl alcohol, Pure, 200 proof, anhydrous, ≥99.5%
Supelco
Acetonitrile, analytical standard
Sigma-Aldrich
Acetonitrile, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
Formic acid, ≥95%, FCC, FG