601411
氟化锂-6Li
95 atom % 6Li, 99% (CP)
登录查看公司和协议定价
选择尺寸
关于此项目
线性分子式:
6LiF
化学文摘社编号:
分子量:
25.01
EC 号:
MDL编号:
UNSPSC代码:
12352302
PubChem化学物质编号:
NACRES:
NA.12
同位素纯度
95 atom % 6Li
质量水平
方案
99% (CP)
表单
solid
mp
842 °C
质量偏移
M-1
储存温度
room temp
SMILES字符串
[6Li+].[F-]
InChI
1S/FH.Li/h1H;/q;+1/p-1/i;1-1
InChI key
PQXKHYXIUOZZFA-HCMAANCNSA-M
正在寻找类似产品? 访问 产品对比指南
包装
这种产品可以散装供应,并可按需包装。有关定价、供货和包装的信息,请联系稳定同位素客户服务。
警示用语:
Danger
危险声明
危险分类
Acute Tox. 3 Oral - Lact. - Repr. 2
储存分类代码
6.1D - Non-combustible acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects
WGK
WGK 3
闪点(°F)
Not applicable
闪点(°C)
Not applicable
法规信息
危险化学品
此项目有
Paola Francisca Caprile et al.
Health physics, 104(2), 218-223 (2013-01-01)
The characteristics of the thermoluminescence glow curve and dosimetric peak of LiF:Mg,Ti (TLD-100) crystals are studied, with emphasis on the evaluation of the influence of the irradiation dose and heating rate on the dosimetric peak (peak 5) trapping parameters. These
Christian Bernhardsson et al.
Health physics, 103(6), 740-749 (2012-11-01)
Laboratory studies have shown that ordinary household salt (NaCl) exhibits several promising properties for retrospective dosimetry; e.g., a linear dose response and a low detection limit, down to a few mGy or even less. In an attempt to test NaCl
A I Abd El-Hafez et al.
Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine, 69(10), 1533-1539 (2011-07-05)
Due to their sensitivity, signal reproducibility and stability, lithium fluoride thermoluminescence dosimeters are widely used in many applications. It was noticed that post-irradiation glow curves of LiF dosimeters that had undergone pre-irradiation background dose measurements dramatically differed from the curves
Thorsten Grünheid et al.
American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics, 141(4), 436-443 (2012-04-03)
Cone-beam computed tomography (CBCT) has become a routine imaging modality for many orthodontic clinics. However, questions remain about the amount of radiation patients are exposed to during the scans. This study determined the amounts of radiation potentially absorbed by a
R Takam et al.
Radiation protection dosimetry, 150(1), 22-33 (2011-08-30)
(6)LiF:Mg,Cu,P and (7)LiF:Mg,Cu,P glass-rod thermoluminescent dosemeters (TLDs) were used for measurements of out-of-field photon and neutron doses produced by Varian iX linear accelerator. Both TLDs were calibrated using 18-MV X-ray beam to investigate their dose-response sensitivity and linearity. CR-39 etch-track
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系客户支持