登录 查看组织和合同定价。
选择尺寸
关于此项目
线性分子式:
6LiF
化学文摘社编号:
分子量:
25.01
NACRES:
NA.12
PubChem Substance ID:
UNSPSC Code:
12352302
EC Number:
238-958-9
MDL number:
Isotopic purity:
95 atom % 6Li
Assay:
99% (CP)
Mass shift:
M-1
Form:
solid
InChI key
PQXKHYXIUOZZFA-HCMAANCNSA-M
InChI
1S/FH.Li/h1H;/q;+1/p-1/i;1-1
SMILES string
[6Li+].[F-]
isotopic purity
95 atom % 6Li
assay
99% (CP)
form
solid
mp
842 °C
mass shift
M-1
storage temp.
room temp
Quality Level
Packaging
这种产品可以散装供应,并可按需包装。有关定价、供货和包装的信息,请联系稳定同位素客户服务。
signalword
Danger
hcodes
Hazard Classifications
Acute Tox. 3 Oral - Lact. - Repr. 2
存储类别
6.1D - Non-combustible acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects
wgk
WGK 3
flash_point_f
Not applicable
flash_point_c
Not applicable
法规信息
危险化学品
此项目有
Asa Carlsson Tedgren et al.
Medical physics, 38(10), 5539-5550 (2011-10-14)
High energy photon beams are used in calibrating dosimeters for use in brachytherapy since absorbed dose to water can be determined accurately and with traceability to primary standards in such beams, using calibrated ion chambers and standard dosimetry protocols. For
Chilin Li et al.
Nano letters, 12(3), 1241-1246 (2012-02-07)
The thermodynamically required redistribution of ions at given interfaces is being paid increased attention. The present investigation of the contact LiF/TiO(2) offers a highly worthwhile example, as the redistribution processes can be predicted and verified. It consists in Li ion
Paola Francisca Caprile et al.
Health physics, 104(2), 218-223 (2013-01-01)
The characteristics of the thermoluminescence glow curve and dosimetric peak of LiF:Mg,Ti (TLD-100) crystals are studied, with emphasis on the evaluation of the influence of the irradiation dose and heating rate on the dosimetric peak (peak 5) trapping parameters. These
Christian Bernhardsson et al.
Health physics, 103(6), 740-749 (2012-11-01)
Laboratory studies have shown that ordinary household salt (NaCl) exhibits several promising properties for retrospective dosimetry; e.g., a linear dose response and a low detection limit, down to a few mGy or even less. In an attempt to test NaCl
R Takam et al.
Radiation protection dosimetry, 150(1), 22-33 (2011-08-30)
(6)LiF:Mg,Cu,P and (7)LiF:Mg,Cu,P glass-rod thermoluminescent dosemeters (TLDs) were used for measurements of out-of-field photon and neutron doses produced by Varian iX linear accelerator. Both TLDs were calibrated using 18-MV X-ray beam to investigate their dose-response sensitivity and linearity. CR-39 etch-track
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.