N-017
去甲哌替啶标准液 溶液
100 μg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
登录查看公司和协议定价
选择尺寸
关于此项目
经验公式(希尔记法):
C14H19NO2
化学文摘社编号:
分子量:
233.31
EC 号:
MDL编号:
UNSPSC代码:
41116107
PubChem化学物质编号:
NACRES:
NA.24
等级
certified reference material
质量水平
表单
liquid
特点
Snap-N-Spike®/Snap-N-Shoot®
包装
ampule of 1 mL
制造商/商品名称
Cerilliant®
drug control
Narcotic Licence Schedule A (Switzerland); estupefaciente (Spain); Decreto Lei 15/93: Tabela IA (Portugal)
浓度
100 μg/mL in methanol
技术
gas chromatography (GC): suitable
liquid chromatography (LC): suitable
应用
forensics and toxicology
包装形式
single component solution
储存温度
−20°C
SMILES字符串
O=C(OCC)C1(C2=CC=CC=C2)CCNCC1
InChI
1S/C14H19NO2/c1-2-17-13(16)14(8-10-15-11-9-14)12-6-4-3-5-7-12/h3-7,15H,2,8-11H2,1H3
InChI key
QKHMFBKXTNQCTM-UHFFFAOYSA-N
正在寻找类似产品? 访问 产品对比指南
一般描述
去甲哌替啶是阿片类镇痛药哌替啶的主要有毒代谢物。 该认证Snap-N-Spike®溶液适用于通过LC-MS/MS、LC/MS 或 GC/MS法进行止痛药处方监测、临床毒理学、尿液药物测试或法医分析。哌替啶是一种具有类似吗啡作用的合成阿片类药物,可用作止痛药。
法律信息
CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany
Snap-N-Shoot is a registered trademark of Cerilliant Corporation
Snap-N-Spike is a registered trademark of Merck KGaA, Darmstadt, Germany
警示用语:
Danger
危险分类
Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1
靶器官
Eyes,Central nervous system
储存分类代码
3 - Flammable liquids
WGK
WGK 2
闪点(°F)
49.5 °F - closed cup
闪点(°C)
9.7 °C - closed cup
法规信息
监管及禁止进口产品
此项目有
E Nissen et al.
Acta paediatrica (Oslo, Norway : 1992), 86(2), 201-208 (1997-02-01)
A standard dose of 100 mg of pethidine was given im to 13 healthy primiparae during labour. The aim of the study was to investigate whether developing breastfeeding behaviour in the newborn infant was associated with the dose-delivery time interval
P Slinger et al.
Journal of cardiothoracic and vascular anesthesia, 9(2), 128-134 (1995-04-01)
It has remained unclear whether epidural opioid analgesia permits better recovery of postthoracotomy pulmonary function than an optimal method of systemic opioid administration. Lumbar epidural meperidine infusions were compared with intravenous patient-controlled analgesic (PCA) meperidine infusions in a prospective randomized
J H Vranken et al.
Acta anaesthesiologica Scandinavica, 49(5), 665-670 (2005-04-20)
Intrathecal administration of meperidine, an opioid with local anesthetic activity, can induce analgesia in patients with intractable cancer pain. However, continuous intrathecal administration may result in the accumulation of normeperidine, responsible for central nervous system toxicity. Ten patients with neuropathic
Evaluation of a disposable device for patient-controlled epidural analgesia after caesarean section.
W D Ngan Kee et al.
Anaesthesia and intensive care, 24(1), 51-55 (1996-02-01)
We evaluated a disposable device (Baxter PCA Infusor) for patient-controlled epidural analgesia (PCEA) using pethidine in twenty women after lower segment caesarean section. Efficacy, as measured by visual analogue pain scores, was comparable with historical controls from PCEA studies using
Detecting the dangers of meperidine.
D Hinnant
Nursing, 25(6), 28-28 (1995-06-01)
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系客户支持