登录 查看组织和合同定价。
选择尺寸
关于此项目
UNSPSC Code:
23151806
NACRES:
NB.24
eCl@ss:
32031690
Material:
high-density polyethylene , high-density polyethylene housing, polyethersulfone membrane, polypropylene housing
Pore size:
0.45 μm pore size
Filtration area:
600 cm2
Feature:
hydrophilic
material
high-density polyethylene , high-density polyethylene housing, polyethersulfone membrane, polypropylene housing
feature
hydrophilic
parameter
0.7 bar max. differential pressure (10 psid), 4.1 bar max. inlet pressure (60 psi)
H
102 mm
diam.
7.6 cm
filtration area
600 cm2
pore size
0.45 μm pore size
bubble point
≥2070 mbar, air with water at 23 °C
fitting
1/8 in. male NPT inlet connection, 1/8 in. male NPT inlet fitting (external threaded connections), 1/8 in. male NPT outlet connection, 1/8 in. male NPT outlet fitting (external threaded connections), stepped hose adapter for ≤ 3/8 in. I.D tubing
application(s)
environmental
shipped in
ambient
Quality Level
General description
These groundwater sampling capsules are an EPA-approved method for collection of groundwater prior to dissolved metal analysis. The pleated membrane provides four times more filtration area than a 142 mm filter disc for faster flow rates and higher throughput.
Features & Benefits:
•Each capsule includes a certificate indicating lowest detectable level (LDL) analysis for 67 metals and 2 anions
•Low-extractable filter and housing materials minimize background during sample analysis
•Available with three different pore sizes to suit a variety of water conditions: 5.0 µm for high particulate levels, 1.0 µm for normal particulate levels, 0.45 µm for relatively clean water
Applications:
Environmental Monitoring, Dissolved Metals Analysis in Water
Features & Benefits:
•Each capsule includes a certificate indicating lowest detectable level (LDL) analysis for 67 metals and 2 anions
•Low-extractable filter and housing materials minimize background during sample analysis
•Available with three different pore sizes to suit a variety of water conditions: 5.0 µm for high particulate levels, 1.0 µm for normal particulate levels, 0.45 µm for relatively clean water
Applications:
Environmental Monitoring, Dissolved Metals Analysis in Water
Application
Disposable, EPA-accepted method for collecting groundwater prior to dissolved metals analysis.
存储类别
10-13 - German Storage Class 10 to 13