跳转至内容
Merck
CN

HCD8MAG15KPX17BK

MILLIPLEX® Human CD8+ T Cell Panel

Bulk (Space Saver) Premixed Human CD8+ T Cell 17-Plex Panel

别名:

17-Plex CD8+ T Cell Panel, 17-Plex Magnetic Bead Panel, CD8+ T Cell Magnetic Bead Panel, Human CD8 T cell cytokine panel, Human cytokine multiplex kit, Luminex® human cytokine immunoassay, Millipore human cytokine panel

登录 查看组织和合同定价。

选择尺寸


关于此项目

UNSPSC Code:
12161503
NACRES:
NA.47
eCl@ss:
32161000
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助

产品名称

MILLIPLEX® Human CD8+ T Cell Panel,

species reactivity

human

Quality Level

description

Bulk (Space Saver) Premixed Human CD8+ T Cell 17-Plex Panel

assay range

standard curve range: 0.4-1,500 pg/mL
(IL-6), standard curve range: 0.5-2,000 pg/mL
(TNFα), standard curve range: 1-3,500 pg/mL
(MIP-1α), standard curve range: 1-5,000 pg/mL
(Granzyme B), standard curve range: 1-5,000 pg/mL
(IFNγ), standard curve range: 1-5,000 pg/mL
(IL-5), standard curve range: 10-50,000 pg/mL
(Perforin), standard curve range: 10-50,000 pg/mL
(sFasL), standard curve range: 2-10,000 pg/mL
(IL-4), standard curve range: 2-10,000 pg/mL
(sCD137), standard curve range: 2-7,500 pg/mL
(IL-13), standard curve range: 2-7,500 pg/mL
(IL-2), standard curve range: 20-100,000 pg/mL
(Granzyme A), standard curve range: 4-15,000 pg/mL
(GM-CSF), standard curve range: 400-1,650,000 pg/mL
(sFas), standard curve range: 5-20,000 pg/mL
(IL-10), standard curve range: 7-30,000 pg/mL
(MIP-1β)

technique(s)

multiplexing: suitable

input

serum plasma (Cell culture, cell culture supernatants)

packaging

pkg of 1 ea

manufacturer/tradename

Milliplex®

detection method

fluorometric (Luminex® xMAP® technology)

shipped in

wet ice

storage temp.

2-8°C

正在寻找类似产品? 访问 产品对比指南

General description

CD8+ T cells (also known as cytotoxic T cells, cytolytic T cells and killer T cells) belong to a sub-group of T cells capable of inducing the death of infected somatic or tumor cells. T cells that bind weakly to Major Histocompatibility Complex (MHC) self-antigens are positively selected into single-positive CD4+ or CD8+ T cells in the thymus. Those CD8+ T cells that survive and mature after activation become cytotoxic cells, expressing T-cell receptors (TCRs) capable of recognizing specific antigenic peptides bound to Class I MHC molecules and the glycoprotein CD8. Affinity between the CD8 protein and the MHC molecule helps to keep the cytotoxic T cell and target closely bound during antigen specific activation. Once activated, CD8+ T cells are generally classified as having a predefined cytotoxic role within the immune system and undergo IL-2 induced clonal expansion, which increases the number of cells specific for the target antigen. The CD8+ T cells then travel throughout the body in search of antigen-positive somatic/tumor cells.

Application

MILLIPLEX® Qualified assays undergo rigorous assay development, verification, and Quality Control testing to achieve optimal performance. Simultaneously analyze 17 analytes in human serum, plasma, and cell culture supernatants.

Analytes included: GM-CSF, sCD137, IFNγ, sFas, sFasL, Granzyme A, Granzyme B, IL-2, IL-4, IL-5, IL-6, IL-10, IL-13, MIP-1α, MIP-1β, TNF-α, Perforin

Assay Characteristics: Refer to kit protocol for assay cross-reactivity, sensitivity, precision, and accuracy.

Features and Benefits

  • Broad Analyte Array: This multiplex assay includes 15 essential analytes that play a role in CD8+ T cell function, such as GM-CSF, IFNγ, IL-2, Granzyme A, and Perforin, enabling comprehensive immune response studies.
  • Deep Insights into Immune Function: Measuring multiple cytokines and chemokines linked to CD8+ T cell activity enhances understanding of the immune response in various diseases, including infections and cancers.
  • Bulk Space Saver Packaging: The bulk packaging option is designed to conserve laboratory space and reduce waste, making it a cost-effective solution for high-volume laboratories while maintaining the integrity of the reagents.
  • Boosted Laboratory Productivity: The multiplex format increases throughput, allowing for the analysis of more samples in less time, which is essential for high-throughput research settings.

Legal Information

Luminex is a registered trademark of Luminex Corp
MILLIPLEX is a registered trademark of Merck KGaA, Darmstadt, Germany
xMAP is a registered trademark of Luminex Corp

Disclaimer

For research use only. Not for use in diagnostic procedures.

Label License/Sticker for Assay Product:

By opening the packaging containing this Assay Product (which contains fluorescently labeled microsphere beads authorized by Luminex Corporation) or using this Assay Product in any manner, you are consenting and agreeing to be bound by the End User Terms and Conditions and the End User License Agreement available at http://support.diasorin.com/end-user-terms-and-conditions/. If you do not agree to all of the terms and conditions, you must promptly return this Assay Product for a full refund prior to using it in any manner.

signalword

Danger

Hazard Classifications

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2

target_organs

Respiratory Tract

存储类别

10 - Combustible liquids

wgk

WGK 3

法规信息

新产品
此项目有

分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系客户支持