跳转至内容
Merck
CN

LSKMAGKP02

PureProteome Kappa Ig Binder Magnetic Beads

The PureProteome Kappa Ig Binder Magnetic Bead System is a powerful system that helps researchers purify all Immunoglobulins with high specificity.

别名:

Kappa Ig Binder Magnetic Beads, PureProteome Magnetic Beads

登录 查看组织和合同定价。

选择尺寸


关于此项目

UNSPSC Code:
41116133
NACRES:
NA.56
eCl@ss:
32160405
Technique(s):
protein purification: suitable (antibody)
Species reactivity:
-
Application:
protein purification
Citations:
3
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助

packaging

pkg of 2 mL

manufacturer/tradename

PureProteome

technique(s)

protein purification: suitable (antibody)

particle size

10 μm

capacity

≥2.2 μg/μL, slurry binding capacity (kappa IgG)

shipped in

wet ice

storage temp.

2-8°C

General description

The PureProteome Kappa Ig Binder Magnetic Beads have been developed with a specialized antibody ligand that specifically targets the human kappa light chain. These magnetic beads offer a fast, scalable, and reliable method for capturing human antibodies or antibody fragments that possess kappa light chains. With high specificity, the Kappa Magnetic Beads bind effectively to the constant region of the kappa light chain found in human immunoglobulins.

Application

PureProteome Kappa Ig Binder Magnetic Beads are suitable:
  • for antibody purification
  • for protein purification
  • to perform coimmunoprecipitation of immune complexes (ICs) in mouse serum to capture host antibody interactions with the circulatory antigens of Trichinella spiralis
  • to capture the immune complexes in the sera of microfilaremic subjects

Features and Benefits

  • More binding sites for proteins due to advanced chemistry and high surface area.
  • Consistent results with no sample loss.
  • Fast processing time.
  • These magnetic beads are more affordable compared to competing alternatives.

Legal Information

PureProteome is a trademark of Merck KGaA, Darmstadt, Germany

Disclaimer

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

存储类别

12 - Non Combustible Liquids

wgk

nwg

flash_point_f

Not applicable

flash_point_c

Not applicable


分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Immunome and immune complex-forming components of Brugia malayi identified by microfilaremic human sera
Reamtong O, et al.
Experimental Parasitology (2019)
Identification and profiling of Trichinella spiralis circulating antigens and proteins in sera of mice with trichinellosis
Charin T, et al.
PLoS ONE (2022)
Identification and profiling of Trichinella spiralis circulating antigens and proteins in sera of mice with trichinellosis
Charin T, et al.
Testing (2022)

商品

PureProteome™ Protein A and G Magnetic beads provide a rapid and reproducible means to purify immunoglobulins (IgG) using the KingFisher Duo particle processor.

通过 PureProteome™ Protein A 和 Protein G 磁珠,可利用 KingFisher Duo 磁珠纯化仪快速、可重现地纯化免疫球蛋白 (IgG)。

相关内容

Immunoprecipitation (IP) is a powerful technique for proteomic screening, biomarker discovery, and signaling network elucidation. It is frequently used to enrich target proteins from complex samples such as cell lysates or extracts. Traditional IP protocols use Protein A, Protein G or a mixture of Protein A and G coupled to a solid support resin, such as agarose beads, to capture an antigen/antibody complex in solution. As the number of samples increase, the traditional, manual IP method can be time-consuming. Processing of multiple IP reactions in parallel can introduce complexity, variability and pipetting errors, which may affect reproducibility.

Traditionally, protein purification from E. coli consists of four distinct phases: harvest, bacterial cell lysis, lysate clarification and protein purification. Bacterial lysis typically requires several time-consuming, hands-on steps, such as freeze/thaw cycles and sonication. These harsh lysis techniques may negatively impact protein quality and contribute to sample-to-sample variability. To maintain protein activity and integrity, detergent-based lysis buffers are routinely used to avoid mechanical protein extraction methods. Regardless of the lysis method used, centrifugation is traditionally required to pellet unwanted cell debris and permit recovery of the clarified lysate. The final step, purification, is frequently performed using affinity media specific for expressed epitope tags. Agarose-based media have typically been used, either as a slurry in microcentrifuge tubes or packed into gravity-driven or spin columns. While easier to manipulate, columns are greatly affected by lysate consistency and carryover of cell debris, which can lead to clogging of the column frits.

Purification of recombinant proteins expressed in E.coli requires many time-consuming steps. To liberate the protein of interest, traditional bacterial lysis relies on the addition of lysozyme and a combination of sonication and repeated freeze/thaw cycles to break the bacterial cell wall. Disruption of the cell is accompanied by an increase in the viscosity of the suspension, due to the release of DNA. An endonuclease is added to digest the DNA, thus reducing the viscosity of the lysate. Finally, to render the lysate compatible with traditional purification methods, insoluble cell debris must be removed by centrifugation.

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系客户支持