2,2,4-三甲基戊烷

≥99.5% (GC)

别名:

异辛烷

登录 查看组织和合同定价。

选择尺寸

变更视图

关于此项目

线性分子式:
(CH3)2CHCH2C(CH3)3
化学文摘社编号:
分子量:
114.23
EC Number:
208-759-1
UNSPSC Code:
12190000
MDL number:
Beilstein/REAXYS Number:
1696876
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助


vapor density

3.9 (vs air)

vapor pressure

41 mmHg ( 21 °C)

assay

≥99.5% (GC)

autoignition temp.

745 °F

expl. lim.

6 %

technique(s)

UV/Vis spectroscopy: suitable

impurities

≤0.0005% non-volatile matter, ≤0.001% free acid (as CH3COOH), ≤0.005% water (Karl Fischer), ≤1 ppb fluorescence (quinine) at 254 nm, ≤1 ppb fluorescence (quinine) at 365 nm

transmittance

210 nm, ≥50%, 220 nm, ≥80%, 230 nm, ≥90%, 245 nm, ≥97%, 255 nm, ≥99%

refractive index

n20/D 1.391 (lit.)

bp

98-99 °C (lit.)

mp

−107 °C (lit.)

density

0.692 g/mL at 25 °C (lit.)

suitability

passes test for IR spectroscopy, passes test for suitability for UV spectroscopy

SMILES string

CC(C)CC(C)(C)C

InChI

1S/C8H18/c1-7(2)6-8(3,4)5/h7H,6H2,1-5H3

InChI key

NHTMVDHEPJAVLT-UHFFFAOYSA-N

Other Notes

Pertains only in Germany: unversteuert


Still not finding the right product?

Explore all of our products under 2,2,4-三甲基戊烷


signalword

Danger

Hazard Classifications

Aquatic Acute 1 - Aquatic Chronic 1 - Asp. Tox. 1 - Flam. Liq. 2 - Skin Irrit. 2 - STOT SE 3

target_organs

Central nervous system

存储类别

3 - Flammable liquids

wgk

WGK 2

flash_point_f

10.4 °F - closed cup

flash_point_c

-12 °C - closed cup

ppe

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter

法规信息

新产品

此项目有



历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库



Swarna Bansal et al.
Journal of hazardous materials, 190(1-3), 45-50 (2011-04-05)
Separation of secondary emulsions of dispersed droplet size less than 10 μm, by means of fibrous medium is a very complex but important process. The study investigates the influence of thin fibrous filter properties, i.e. surface energy, pore size and
Yufeng Zhang et al.
Journal of chromatography. A, 1252, 67-73 (2012-07-10)
In this study, a polyethylene Pasteur pipette-based ultrasound-assisted emulsification microextraction (USAEME) applying low-density organic solvent was successfully developed for the extraction of trace levels of organochlorine pesticides (OCPs) in water samples and followed by gas chromatography-mass spectrometry (GC-MS) analysis. In
Kyung Min Park et al.
Food chemistry, 138(2-3), 733-738 (2013-02-16)
In this study, we investigated the possibility of reversed micelles, widely used as an enzyme reactor for lipases, for the determination of lipoxygenase activity. Although it is rapid and simple, reversed micelles have some limitations, such as interference by UV-absorbing