InChI key
UWSMKYBKUPAEJQ-UHFFFAOYSA-N
InChI
1S/C20H24ClN3O/c1-19(2,3)12-9-14(20(4,5)6)18(25)17(10-12)24-22-15-8-7-13(21)11-16(15)23-24/h7-11,25H,1-6H3
SMILES string
CC(C)(C)c1cc(c(O)c(c1)C(C)(C)C)-n2nc3ccc(Cl)cc3n2
grade
certified reference material, TraceCERT®
product line
TraceCERT®
shelf life
limited shelf life, expiry date on the label
technique(s)
HPLC: suitable, gas chromatography (GC): suitable
mp
150-153 °C (lit.)
application(s)
cleaning products
cosmetics
environmental
food and beverages
personal care
format
neat
Quality Level
正在寻找类似产品? 访问 产品对比指南
General description
This certified reference material (CRM) is produced and certified in accordance with ISO/IEC 17025 and ISO 17034. This CRM is traceable to primary material from an NMI, e.g. NIST or NMIJ.
Certified content by quantitative NMR incl. uncertainty and expiry date are given on the certificate.
Download your certificate at: http://www.sigma-aldrich.com.
Certified content by quantitative NMR incl. uncertainty and expiry date are given on the certificate.
Download your certificate at: http://www.sigma-aldrich.com.
This compound is listed in the SVHC (Substances of very high concern) candidate list of ECHA (European Chemicals Agency)
This substance is listed on the positive list of the EU regulation 10/2011 for plastics intended to come into contact with food.
Other Notes
Ion Mobility: TWCCSN2 value of 193.6 Å2 [M+H]+, 204.7 Å2 [M+Na]+ and 199.8 Å2 [M-H]-
The collision cross section (CCS) measurement was provided by Waters Corporation, using the SYNAPT XS mass spectrometer.
For a description and overview of how ion mobility enables the measurement of the CCS of an ion visit ims.waters.com.
Further information on the SYNAPT XS mass spectrometer can be found on the IMS microsite and product webpage.
TWCCS measurements are expected to be within 2% of this reference value.
P/N 49751 is part of the Waters Extractables & Leachables UNIFI scientific library which can be downloaded from Waters Marketplace.
The collision cross section (CCS) measurement was provided by Waters Corporation, using the SYNAPT XS mass spectrometer.
For a description and overview of how ion mobility enables the measurement of the CCS of an ion visit ims.waters.com.
Further information on the SYNAPT XS mass spectrometer can be found on the IMS microsite and product webpage.
TWCCS measurements are expected to be within 2% of this reference value.
P/N 49751 is part of the Waters Extractables & Leachables UNIFI scientific library which can be downloaded from Waters Marketplace.
Legal Information
TraceCERT is a registered trademark of Merck KGaA, Darmstadt, Germany
存储类别
11 - Combustible Solids
wgk
WGK 2
flash_point_f
Not applicable
flash_point_c
Not applicable
signalword
Danger
hcodes
Hazard Classifications
Aquatic Chronic 3 - STOT RE 2 - vPvB
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系客户支持