跳转至内容
Merck
CN

71644

磷酸钠 二元 二水合物

BioUltra, ≥99.0% (T)

别名:

sec-磷酸钠, 磷酸二钠, 磷酸氢二钠 二水合物

登录 查看组织和合同定价。

选择尺寸

变更视图

关于此项目

线性分子式:
Na2HPO4 · 2H2O
化学文摘社编号:
分子量:
177.99
UNSPSC Code:
12352200
PubChem Substance ID:
EC Number:
231-448-7
MDL number:
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助


product line

BioUltra

assay

≥99.0% (T)

form

crystals

impurities

insoluble matter, passes filter test, ≤0.001% total nitrogen (N)

pH

8.9-9.2 (25 °C, 0.5 M in H2O)

solubility

H2O: 0.5 M at 20 °C, clear, colorless

anion traces

chloride (Cl-): ≤10 mg/kg, sulfate (SO42-): ≤50 mg/kg

cation traces

Al: ≤5 mg/kg, As: ≤0.1 mg/kg, Ba: ≤5 mg/kg, Bi: ≤5 mg/kg, Ca: ≤10 mg/kg, Cd: ≤5 mg/kg, Co: ≤5 mg/kg, Cr: ≤5 mg/kg, Cu: ≤5 mg/kg, Fe: ≤5 mg/kg, K: ≤50 mg/kg, Li: ≤5 mg/kg, Mg: ≤5 mg/kg, Mn: ≤5 mg/kg, Mo: ≤5 mg/kg, Ni: ≤5 mg/kg, Pb: ≤5 mg/kg, Sr: ≤5 mg/kg, Zn: ≤5 mg/kg

λ

0.5 M in H2O

UV absorption

λ: 260 nm Amax: 0.03, λ: 280 nm Amax: 0.03

SMILES string

O.O.[Na+].[Na+].OP([O-])([O-])=O

InChI

1S/2Na.H3O4P.2H2O/c;;1-5(2,3)4;;/h;;(H3,1,2,3,4);2*1H2/q2*+1;;;/p-2

InChI key

KDQPSPMLNJTZAL-UHFFFAOYSA-L



Still not finding the right product?

Explore all of our products under 磷酸钠 二元 二水合物


flash_point_f

Not applicable

存储类别

13 - Non Combustible Solids

wgk

WGK 1

flash_point_c

Not applicable

ppe

Eyeshields, Gloves, type N95 (US)

法规信息

新产品

此项目有



历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 文件 section.

如需帮助,请联系 客户支持

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库



Christopher Polonyi et al.
Dalton transactions (Cambridge, England : 2003), 43(31), 11941-11949 (2014-06-27)
The ability of the anticancer active drug cisplatin to exert biological activity through interference with nucleic acid function is well documented. Since kinetics play a key role in determining product distributions in these systems, methods for accurate documentation of reactivity
Susann K J Ludwig et al.
Analytical and bioanalytical chemistry, 406(27), 6857-6866 (2014-06-29)
Current contaminant and residue monitoring throughout the food chain is based on sampling, transport, administration, and analysis in specialized control laboratories. This is a highly inefficient and costly process since typically more than 99% of the samples are found to
Anna Flis et al.
Pharmacological reports : PR, 67(1), 1-8 (2015-01-07)
Human prostate cancer (hPCa) is the most commonly diagnosed cancer in elderly men and is the second leading cause of male cancer death. Data from epidemiological, eco-environmental, nutritional prevention and clinical trials suggest that selenium Se(IV) can prevent prostate cancer.