vapor pressure
1 mmHg ( 20 °C)
grade
purum
assay
≥98.0% (GC)
refractive index
n20/D 1.429 (lit.), n20/D 1.430
bp
175-177 °C (lit.)
mp
−5-−1 °C (lit.)
density
0.782 g/mL at 25 °C (lit.)
SMILES string
CCCCCCCCN
InChI
1S/C8H19N/c1-2-3-4-5-6-7-8-9/h2-9H2,1H3
InChI key
IOQPZZOEVPZRBK-UHFFFAOYSA-N
正在寻找类似产品? 访问 产品对比指南
signalword
Danger
Hazard Classifications
Acute Tox. 3 Dermal - Acute Tox. 3 Oral - Acute Tox. 4 Inhalation - Aquatic Acute 1 - Aquatic Chronic 2 - Eye Dam. 1 - Flam. Liq. 3 - Skin Corr. 1A - STOT SE 3
target_organs
Respiratory system
存储类别
3 - Flammable liquids
wgk
WGK 3
flash_point_f
140.0 °F - closed cup
flash_point_c
60 °C - closed cup
ppe
Faceshields, Gloves, Goggles, type ABEK (EN14387) respirator filter
法规信息
新产品
此项目有
Vera Bocharova et al.
Small (Weinheim an der Bergstrasse, Germany), 2(7), 910-916 (2006-12-29)
Spin-coating of isolated positively charged macromolecules onto mica in the presence of octylamine was found to be a simple and general method of stretching and aligning the macromolecular chains. The contour length and molar mass for the stretched macromolecules can
Hong Zheng et al.
Journal of biomedical nanotechnology, 7(5), 648-658 (2011-12-27)
Quantum dots (QDs) have emerged as alternative or complementary tools to organic fluorescent dyes currently used in bioimaging. QDs hold several advantages over conventional fluorescent dyes including greater photostability and a wider range of excitation/emission wavelengths. However, recent work suggests
Rosario Zamora et al.
Journal of agricultural and food chemistry, 54(6), 2398-2404 (2006-03-16)
The reactions of 4,5-epoxy-2-decenal with octylamine, benzylamine, and 2-phenylglycine methyl ester were studied to investigate if amines may suffer a Strecker type degradation by epoxyalkenals analogously to amino acids. In addition to other reactions, the studied amines were converted into
J A Ocaña González et al.
Journal of pharmaceutical and biomedical analysis, 36(1), 117-123 (2004-09-08)
A liquid chromatographic method with UV detection for simultaneous determination of cefepime and grepafloxacin has been developed. The method uses a C18 column, equipped with a pre-column of the same material, and acetonitrile-0.1 M phosphoric acid/sodium hydroxide buffer (pH 3.0)-0.01
Brad A Kairdolf et al.
Analytical chemistry, 80(8), 3029-3034 (2008-03-08)
Quantum-dot (QD) nanocrystals are promising fluorescent probes for multiplexed staining assays in biological applications. However, nonspecific QD binding to cellular membranes and proteins remains a limiting factor in detection sensitivity and specificity. Here we report a new class of hydroxyl
全球贸易项目编号
| 货号 | GTIN |
|---|---|
| 332844-25G | 04061831819762 |
| 332844-5G | 04061831810608 |
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系客户支持


